ipAddrSet 0
b. Type the requested information for this IP address at the prompt:
Ethernet IP Address [10.77.77.77]:
Ethernet Subnetmask [0.0.0.0]:
Fibre Channel IP Address [none]:
Fibre Channel Subnet Mask [none]:
The logical IP address is updated immediately.
c. To configure the second logical IP address, type the following command at
the prompt:
ipAddrSet 1
d. Type the requested information for this IP address at the prompt.
e. At the prompt, type the following command to restart the CP card:
reboot
Note: You can use the terminal serial port to monitor error messages
through a serial connection. Do not use the terminal serial port as a
command line interface during normal operations because it only
modifies one switch at a time (switch 0 by default).
f. If this port is not used continuously, remove the serial cable. Replace the
shipping cap to protect the port from dust.
6. Optional: Connect the active CP card by Ethernet cable to the local area
network (LAN).
a. Remove the shipping plug from the Ethernet port on the active CP card.
b. Insert one end of an Ethernet cable into the Ethernet port.
c. Connect the other end to an Ethernet 10/100BASE-T LAN.
You can now access the switch remotely by using any of the available
management tools, such as Telnet or Web Tools. Be sure that the switch is not
modified from other connections during the rest of this procedure.
7. Optional: Login to either of the logical switches by using Telnet and the
administrative logon. The default administrative logon name is admin, and the
default password is password.
You can now access the switch remotely using Telnet or Web Tools. Be sure
that the switch is not being modified from any other connections during the
remaining steps. The M12 supports up to two Telnet sessions with
administrative privileges at the same time. You can accomplish the remaining
steps in this procedure with either a serial connection or a Telnet session.
8. Optional: Customize the switch names for the logical switches, if desired. If
possible, use the default switch names.
Note: Changing the name of the switch causes a domain address format
RSCN to be issued.
a. Type switchName, with the new switch name enclosed in double quotation
marks. In the following example, "sw10" is the new switch name.
switchName "sw10"
b. Record the new switch name for future reference.
c. To customize the switch name for the other logical switch, perform the
following steps:
1) Log out from the CP session.
2) Connect the serial cable to the other CP card.
Chapter 2. Starting and configuring the M12