Table 3 describes the 16–port card LED patterns. It lists the name, location, and
possible colors of each LED. It also lists the status of the switch that is associated
with each LED color and the action that you can take in response to that status.
Table 3. 16–port card LED patterns
Name of LED
Location of LED Color of LED
Power
Uppermost LED
Status
Below the Power
LED
Port Speed
Uppermost of the
two LEDs to the
left of each port
22
IBM TotalStorage SAN Switch: 2109 Model M12 Installation and Service Guide
No light (LED is off)
Steady green
No light (LED is off)
Steady yellow
Slow-flashing yellow (on
2 seconds; off 2
seconds)
Fast-flashing yellow (on
1/2 second; off 1/2
second)
No light (LED is off)
Steady green
Status of hardware
Action
The 16–port card does
Ensure that the card is
not have incoming
firmly seated and has
power.
power.
The 16–port card has
No action is required.
incoming power.
The 16–port card is
Verify that the Power LED
either healthy or does
is lit.
not have power.
The 16–port card is
Ensure that the card is
faulty.
firmly seated and check the
status with the slotShow
command. If the LED still
displays yellow, contact
IBM.
The 16–port card is not
Pull the card out and reseat
seated correctly, or is
it. If the LED continues to
faulty.
flash, replace the card.
The environmental
Check for out-of-bounds
range is exceeded.
environmental condition.
The port is either set to
Verify that the Power LED
1 Gbps mode, or does
is lit. To change the mode,
not have incoming
see the Brocade Fabric OS
power.
Procedures Guide.
The port is set to 2
No action is required.
Gbps mode.