Table 20. General specifications (continued)
Specification
EMI rating
System architecture
System processor
ANSI fibre channel protocol
Modes of operation
Fabric initialization
Internet protocol (IP) over Fibre Channel
(FC-IP)
Aggregate switch input/output (I/O)
bandwidth
Port-to-port latency
Data transmission range
Immunity
Acoustics
Routing capacity
Description
An operating M12 conforms to the EMI
radiation levels specified by the following
regulations:
v FCC Rules and Regulations, Part 15B,
Class A level
v CISPR22 Class A
v EN55022 Class A
v VCCI Class A ITE
v AS/NZS 3548 Class A
v CNS13438 Class A
v ICES–003 Class A
Nonblocking shared-memory switch
IBM Power PC 405GP, 200 MHz CPU
FC–PH (Fibre Channel Physical and
Signaling Interface standard)
Fibre Channel Class 2, Class 3, and Class F
Complies with FC–SW 5.0
Complies with FC–IP 2.3 of the FCA profile
Per port: 4 Gbps, running at 2 Gbps, full
duplex
Per 16–port card: 64 Gbps, all 16 ports at 2
Gbps, full duplex
Less than 2 microseconds with no contention
(destination port is free)
v Up to 500 m (1625 ft) for short wavelength
optical link
v Up to 10 km (32 820 ft) for long
wavelength optical link
v IEC 61000–4–2 Severity Level 3 for
Electrostatic Discharge
v IEC 61000–4–3 Severity Level 3 for
Radiated Fields
v IEC 61000–4–4 Severity Level 3 for Fast
Transients
v IEC 61000–4–5 Severity Level 3 for Surge
Voltage
v IEC 61000–4–6 Conducted Emissions
v IEC 61000–4–11 Voltage Variations
When measured in EIA 4 of a 36 EIA
TotalStorage rack, with front cover, and rear
cover with acoustic baffle, declared sound
power is LwAd = 7.5 B, average bystander
sound pressure is LpA = 59 dBA.
A minimum aggregate routing capacity of
four million frames per second is provided for
Class 2, Class 3, and Class F frames in a
64–port switch.
Appendix A. Product specifications
91