3 • Basic Operation
Envelope
Options
(continued)
3-32
Menu Item
Associated Options and Actions
Additional Settings
Double Detect allows the system sense when multiple envelopes
are fed unintentionally.
Note: This menu option is not available when the job re-
quires a custom feeder.
Feeder Type allows you to change the Feeder setting when
material is problematic.
NOTE: The Special Feeder is a purchasable option. If available,
it will be located at the top left or right of the Feeder Tower. It is
an option for one or more tower feeders to improve feeding of
thin prefolded items or booklets with thin covers. It reduces the
tendency of these items to separate while they are being fed. You
must push the "Special Feeder" lever up to run a job when the
Feeder Type is set to Special Feeder.
Feeder Linking allows multiple Feeders to feed the same
envelope.
NOTE: Feeders must be on the same module and on the same
side of the tower to be linked. For scanned items, always load
linked feeders at a collation break.
Double Detect Feature allows you to toggle:
-
Off means this feature will not function for this item, or
-
On means this feature is active.
Location allows you to toggle:
-
Default, or
-
Custom.
Custom Location for Top Edge allows you to enter a specific
measurement (distance from the edge feeding first into the
feeder) where the system should attempt to detect a double.
Set this option when Location is set to "Custom".
-
Use the UP/DOWN arrow keys to adjust the measurement
(in millimeters).
-
Select "Accept" when you are done.
NOTE: The double detect region cannot be within 1-inch (25
mm) of the lead or trail edges of the envelope.
If the envelope is feeding from the HCEF, measure from the
bottom of the envelope.
If the envelope is feeding from the Feeder Tower, measure
from the top of the envelope. The custom location must be at
least .2 inches (5mm) away from the edge of the window (if
present), at least .2 inches (5mm) away from the edge of flap,
and cannot lie on top of a seam.
For best results, be sure to avoid areas that overlap with the
window, flap, or seams.
Action On Double allows you to select where the items should
be fed to if a double is detected.
Normal is used for most items.
Special Feeder helps problematic material run better.
None means there is no linking of Feeder Trays.
Two Feeders indicates that two Feeder Trays are linked and
feeding the same material.
SV63136 Rev. A