Problem
Stoppage in tower area.
Problem
Stoppage in folder.
Stoppage in inverter.
SV63136 Rev. A
Table 5-4 Tower Area Problems
Cause
Material not within
specifications, causing skew.
Improper loading: material
skew caused by Tower
feeders.
Paper fragments or other
obstruction in transport.
Flexible plastic material
guides in Tower area are
broken or displaced.
Table 5-5 Folder/Inverter Problems
Cause
Paper fragments.
Material not within
specifications.
Troubleshooting • 5
Action
Check that all material meets published specifications.
Refer to Feeder Tower Material Specifications in
Chapter 6 of this guide for instructions.
•
Remove curled or warped material.
•
Use only material that has been stored properly.
NOTE: High humidity can make paper limp and
cause curling. Additionally, recycled material can
sometimes be problematic.
Check Side Guide adjustment on Trays. Skewed
material is a common cause of problems in the Tower
area. Refer to Adjusting Tray Side Guides in Chapter 3
of this guide for instructions.
Inspect. Clean.
Open Tower cover and inspect. If replacement is
necessary, call your system supplier.
Flexible
plastic
material
guides
Action
•
Open Folder and check for obstruction.
•
Remove paper fragments/residues.
Check that material meets specifications.
NOTE: Sets that use the inverter cannot be wider than
9 inches ( 225mm).
5-11