Pitney Bowes Relay 5000 Operator's Manual page 107

Hide thumbs Also See for Relay 5000:
Table of Contents

Advertisement

Problem
Stoppage in tower area.
Problem
Stoppage in folder.
Stoppage in inverter.
SV63136 Rev. A
Table 5-4 Tower Area Problems
Cause
Material not within
specifications, causing skew.
Improper loading: material
skew caused by Tower
feeders.
Paper fragments or other
obstruction in transport.
Flexible plastic material
guides in Tower area are
broken or displaced.
Table 5-5 Folder/Inverter Problems
Cause
Paper fragments.
Material not within
specifications.
Troubleshooting • 5
Action
Check that all material meets published specifications.
Refer to Feeder Tower Material Specifications in
Chapter 6 of this guide for instructions.
Remove curled or warped material.
Use only material that has been stored properly.
NOTE: High humidity can make paper limp and
cause curling. Additionally, recycled material can
sometimes be problematic.
Check Side Guide adjustment on Trays. Skewed
material is a common cause of problems in the Tower
area. Refer to Adjusting Tray Side Guides in Chapter 3
of this guide for instructions.
Inspect. Clean.
Open Tower cover and inspect. If replacement is
necessary, call your system supplier.
Flexible
plastic
material
guides
Action
Open Folder and check for obstruction.
Remove paper fragments/residues.
Check that material meets specifications.
NOTE: Sets that use the inverter cannot be wider than
9 inches ( 225mm).
5-11