Replacing
the Moistener
Brushes
(continued)
SV63136 Rev. A
2. Remove old brushes:
a. Hold the blue brush holder in place with one hand while you use the
other hand to push the bristles of the old brush completely free from
the holder.
NOTE: You will be pushing the bristles toward yourself .
b. Repeat for all three brushes and discard.
3. Install the new brushes:
NOTE: Avoid bending or deforming the brush bristles; permanent distortion
of the bristles will prevent envelopes from sealing correctly.
a. Hold the blue brush holder in place with one hand.
b. Insert the metal edge of the new brush into the channel opening in
front of the brush holder.
c. Slightly push the brush into the channel of the brush holder to start it.
d. Slide the new brush completely into the holder by its bristles until it
stops.
NOTE: The brush is completely inserted when there is no more visible
metal edge of the brush extending out from the front of the brush holder..
e. Repeat for the remaining two brushes.
Troubleshooting • 5
5-21