Result
The Thor VM3 continues to run and follows the Auto-On power scheme with timers
reset at the time power was connected.
UPS Mode
This mode is selected any time external power is not present, regardless of selected
Power Configuration. Ignition Input is ignored.
Thor VM3 is Off
Conditions
Result
The Thor VM3 boots and follows the UPS power scheme with power management tim-
ers reset at boot up.
Conditions
The Thor VM3 is Off and the power button is pressed the Thor VM3 and at least one of
the following conditions are met:
Results
The Thor VM3 remains Off.
Thor VM3 is On
Conditions
The Thor VM3 is On and external power is removed, such as:
Result
The Thor VM3 continues to run and follows the UPS mode power scheme with power
management timers reset at the time of power removal. UPS charging is disabled.
200
Thor VM3 is already mounted to a dock and external power is applied to the dock
Thor VM3 is already mounted to a dock and the dock power switch is turned On
The Thor VM3 is Off and the power button is pressed the Thor VM3 and both the
following conditions are met:
UPS power is over 10% capacity
CPU temperature is over 20ºC
UPS power is under 10% capacity
CPU temperature is under 20ºC
Thor VM3 is removed from a powered dock (Dock power switch On)
Thor VM3 is mounted to a dock and truck power is removed from the dock
Thor VM3 is mounted to a dock and the dock power switch is turned Off