Radio Configurations, RBS 2106 and RBS 2206
Table 26
SCC
Configuration
1 x 2
G8d_2.2
G8dt_2.2
G9de_2.2
G9det_2.2
G18d_2.2
G18dt_2.2
G19d_2.2
G19dt_2.2
2 x 2
2 x G8d_2.2
2 x G8dt_2.2
2 x G9de_2.2
2 x G9det_2.2
2 x G18d_2.2
2 x G18dt_2.2
2 x G19d_2.2
2 x G19dt_2.2
M = Mandatory
1)
It is possible to mix cells with TMA and cells without TMA in the
same cell.
72 (485)
CDU-G configurations without hybrid combiner in a partly-equipped cabinet only
TMA
No
M
No
M
No
M
No
M
No
M
No
M
No
M
1)
No
1)
M
© Ericsson Radio Systems AB
— All Rights Reserved —
Number of
Allowed Number of dTRUs
Antennas
(2) (0) (0)
(0..1) (0) (0)
(2) (0) (0)
(0..1) (0) (0)
(2) (0) (0)
(0..1) (0) (0)
(2) (0) (0)
(0..1) (0) (0)
(2) (0) (0)
(0..1) (0) (0)
(2) (0) (0)
(0..1) (0) (0)
(2) (0) (0)
(0..1) (0) (0)
(2) (0) (0)
(0..1) (0) (0)
(2) (2) (0)
(0..1) (0..1) (0)
(2) (2) (0)
(0..1) (0..1) (0)
(2) (2) (0)
(0..1) (0..1) (0)
(2) (2) (0)
(0..1) (0..1) (0)
(2) (2) (0)
(0..1) (0..1) (0)
(2) (2) (0)
(0..1) (0..1) (0)
(2) (2) (0)
(0..1) (0..1) (0)
(2) (2) (0)
(0..1) (0..1) (0)
EN/LZT 720 0008
P2A
2001-11-28