Ericsson RBS 2106 Reference Manual page 390

Hide thumbs Also See for RBS 2106:
Table of Contents

Advertisement

Operation and Maintenance Terminal
48.3.12
PCM Network
The following user functions, related to the PCM network, are available
in the OMT:
388 (485)
Current Supervision Limit Low
Current Supervision Limit High
It is possible to define values for the following parameters only in
OMT state LOCAL:
– RX Group Delay
– Loss
– RX Frequency Range
RX Frequency Low
RX Frequency High
Display ALNA/TMA parameters, displays any of the following
parameters associated with ALNA/TMA:
– Current Supervision Limits
Current Supervision Limit Low
Current Supervision Limit High
– RX Group Delay
– Loss
– RX Frequency Range
RX Frequency Low
RX Frequency High
Set transmission interface type, sets transmission interface type in
the database to G.703 2048 kbit/s or DS1 1544 kbit/s.
Modify available synchronization source sets whether PCM link A
and B, or anyone of them is to be available as synchronization
source. Possible settings are: Activated or Not activated.
Display available synchronization source displays whether PCM
link A and B, or anyone of them is available as synchronization
source. Possible settings are: Activated or Not activated.
Set Network_topology value.
Sets Network_topology value for stand alone or cascade
connection of RBSs.
Display Network_topology value.
Displays whether the network topology of the RBSs is stand alone
or cascade connection.
Define TF Compensation Value
© Ericsson Radio Systems AB
— All Rights Reserved —
EN/LZT 720 0008
P2A
2001-11-28