Ericsson RBS 2106 Reference Manual page 121

Hide thumbs Also See for RBS 2106:
Table of Contents

Advertisement

6.4.4
Foot Print
Unit of measurement: mm
Figure 51
The RBS 2206 has the same footprint as both cabinets in the RBS 200
system, and the RBS 2202 cabinet. The base frame is used as a
template to mark new holes for the RBS 2206.
Replacements
The RBS 2206 cable interfaces are different from the RBS 200 and the
RBS 2202. New power distribution circuit breakers and new matching
power cables may have to be installed between the power distribution
board and the cabinet, see Section 6.3 Power Connections on page 110.
Make sure the existing feeders and other cables reach the radio cabinet
and that the battery back-up cables have the correct cross-sectional area.
6.4.5
Power Consumption
Table 61
RBS (fully
equipped)
Maximum power
consumption
(1) Power consumption during maximum battery charging.
The RBS 2206 has capacity to supply units with power up to 4.8 kW.
The power consumption during operation depends upon configuration
and traffic.
6.4.6
Heat Dissipation
All power consumed by the RBS can be considered as heat dissipation
in the RBS room.
EN/LZT 720 0008
P2A
2001-11-28
o 20x75
(RBS 2202)
RBS 2206
99
Drilling template for RBS 2206
Power consumption for RBS 2206
Power Supply Voltage
120 - 250 V AC
3.9 kW/ 5.8 kW
© Ericsson Radio Systems AB
— All Rights Reserved —
Product Data RBS 2206
45
220
320 400
FRONT
400
598
+24 V DC
(1)
3.2 kW
P008315A
-48 V DC
3.8 kW
119 (485)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rbs 2206

Table of Contents