Ericsson RBS 2106 Reference Manual page 456

Hide thumbs Also See for RBS 2106:
Table of Contents

Advertisement

Transport network O&M functions-DXX Support
Each of the statistics are supported by two groups of registers and two
groups of counters providing the performance data. The registers and
counters can be read and reset.
They are:
The information of the 15 minutes counters and registers are sent
together in one report. The information of the 24 hours counters and
registers are sent together in another report.
G.821 limits alarm
An alarm is activated when at least one G.821 performance limit has
been executed in a 15–minute period. The performance limits can be
changed from DXX.
The G.821 Performance limits supervised are:
G.821 Performance basic statistics counters
For limited statistics a number of counters are reported with a
performance counter value. The counters can be read and reset on
request.
The following counters are supported:
Description of performance data
AT
454 (485)
Counters for current 15 minutes report
Registers for previous 15 minutes report
Counters for current 24 hours report
Registers for previous 24 hours report
Limit for Severely Errored Seconds (SES), with the values
between 0 and 900.
Limit for Errored Seconds (ES), with the values between 0 and
900.
Limit for CRC-E, with the values between 0 and 65000.
Limit for Remote Alarm Indication (RAI), with the value between
0 and 900.
Total Time (TT)
Available Time (AT)
Severely Errored Seconds (SES)
Errored Seconds (ES)
Degraded Minutes (DM)
© Ericsson Radio Systems AB
— All Rights Reserved —
Available time is the total time (TT)
minus unavailable time (UAT).
A period of unavailable time (UAT)
begins at the onset of 10 consecutive SES.
These 10 seconds are considered to be
EN/LZT 720 0008