Table 112
Indicator
Fault
Operational
EPC bus fault
15.1.5
Input Data
Table 113
Nominal input voltage
Permitted variation input voltage
Frequency
Current
Inrush current
Internal fuse
Efficiency
Power factor
Non-destructive voltage
Pulses < 20 ms
Max. power consumption
Max. heat generation
1)
90 V AC with reduced output power.
15.1.6
Output Data
Table 114
Nominal output voltage
Preset output voltage
Voltage range
Ouput power (108 - 275 V)
Output power (90 - 108 V)
Output current at 27.2 V DC
15.1.7
Dimensions and Weight
Table 115
Height
Width
Depth
Weight
EN/LZT 720 0008
P2A
2001-11-28
Input data
Output data
PSU Dimensions and weight
© Ericsson Radio Systems AB
— All Rights Reserved —
Unit Description, PSU 1200 W
Colour
Red
Green
Yellow
120 to 250 V AC
1)
108
to 275 V AC
45-65 Hz
< 8A (at 180 - 275 V AC)
<12 A (at 108 - 140 V AC)
< 30 A peak
15 A (slow)
> 83%
cos ϕ > 0.95
0 - 300 V AC
300 V AC
1446 V A
246 W
+24 V DC
+27.2 ±0.1 V DC
+22 to +29 V DC
1200 W
1000 W
36.8 A at 90 - 108 V AC
44.1 A at 108 - 275 V AC
262 mm
61 mm
225 mm
3.3 kg
189 (485)