Advertisement

Table 174
Limit standard
Test level
Performance
Table 175
Limit standard
Test level
Performance
Table 176
Basic standard
Test level
Performance
Table 177
Limit standard
Test level
Performance
52.3.7
Radiated Immunity of Enclosure Port
Table 178
Basic standard
Test level
Performance
Limit standard
Test level
Frequency range
Performance
EN/LZT 720 0008
P2A
2001-11-28
Surge test 1.2/50 pulses
EN 61000-4-5
2 kV common mode between line and cabinet ground reference
1 kV differential mode between line and line
Criteria B for a complete system
Criteria TT for transmitter units
Criteria TR for receiver units
Surge test 10/700 pulses
EN 61000-4-5
1 kV common mode between line and cabinet ground reference
1 kV differential mode between line and line
Criteria B for a complete system
Criteria TT for transmitter units
Criteria TR for receiver units
Power induction test
ITU-T K.20
600 V(rms) common mode
Criteria A(K.20)
RF common mode test
ETS 300 342-2
10 V(rms)
Criteria A for a complete system
Criteria CT for transmitter units
Criteria CR for receiver units
Immunity of continuous electric fields
IEC 801-3
10 V/m
Criteria A
ETS 300 342-2
10 V/m, 80 MHz - 1 GHz
30 V/m, 1 GHz-20 GHz
Criteria A for a complete system