Ericsson RBS 2106 Reference Manual page 417

Hide thumbs Also See for RBS 2106:
Table of Contents

Advertisement

performed when the AO DP is in state "Enable". When the AO DP is
enabled, all fault supervision states are set to zero.
Reports are sent to the BSC is sent to the BSC when the alarm status is
changed or when the BSC requires it.
Fault supervision of the PCM line is performed according to /ITU-T
rec. G.732 section 4/ and /GSM:08.54:4.0.0/.
This includes detection of the following fault conditions:
Fault handling is according to Diagnostic and Fault Handling
functionality.
LOF commences
CRC-4 is OFF: Three consecutive frame alignment signals in TS0
received with an error.
CRC-4 is ON: CRC multiframe alignment has not been achieved within
a search time of 500 ms or three consecutive frame alignment signals in
TS0 received with an error or CRC multiframe alignment is lost during
monitoring for incorrect frame alignment (≥915 errored CRC blocks out
of 1000).
LOF ceases
CRC-4 is OFF: Recovery of frame alignment signal.
CRC-4 is ON: Recovery of CRC multiframe alignment signal.
CSES commences
More than N SES (Severely Errored Seconds) detected consecutively.
The criteria for SES are described in the section Severely Errored
Seconds Supervision.
This condition is set instead of ERATE when quality supervision
including CRC-4 is used.
CSES ceases
More than N non-SES detected consecutively.
ERATE commences
Detection of bit error ratio equal to or more than 10
EN/LZT 720 0008
P2A
2001-11-28
Transmission Interface Handling G.703 2048 kbit/s
LOF (Loss of Frame Alignment)
CSES (Consecutive Severely Errored Seconds) or excessive bit
ERATE (Error RATE)
LOS (Loss Of incoming Signal)
AIS (Alarm Indication Signal)
RAI (Remote Alarm Indication)
UAST (UnAvailable STate supervision)
© Ericsson Radio Systems AB
— All Rights Reserved —
–3
.
415 (485)