Ericsson RBS 2106 Reference Manual page 162

Hide thumbs Also See for RBS 2106:
Table of Contents

Advertisement

Unit Decription, CDU-G and CDU-F
TX Part Description
CDU-G consists of two identical TX chains.
The TX part contains a lowpass filter and a duplex filter. The lowpass
filter secures the required reverse isolation. It also reduces spuriouses
from the transmitter on the frequencies higher than the TX band. The
duplex filter (DPX) allows using a single antenna for both transmitting
and receiving.
There is an Measurement Coupler Unit (MCU) between the DPX and
antenna connector. The MCU samples forwarded and reflected signals
and distributes them to the Measurement Receiver (MR) for antenna
return loss monitoring.
RX Part Description
CDU-G consists of two identical RX chains.
The RX parts consist of a filter and a low noise amplifier (LNA). The
receiving filter is included in the duplex filter.
Distribution of RX signals is performed in the Configuration Switching
Unit (CXU).
Block Diagram
Figure 90
160 (485)
TXLP
DPX MCU
Tx 1
Filter unit 1
Rx 1
Rx 2
Filter unit 2
Tx 2
TXLP
DPX
Block diagram of CDU-G
© Ericsson Radio Systems AB
— All Rights Reserved —
TX/RX 1
CDU Bus
MR
DC in
TX/RX 2
MCU
EN/LZT 720 0008
P007449B
P2A
2001-11-28

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rbs 2206

Table of Contents