Transmission Interface Handling G.703 2048 kbit/s
The number of unavailable seconds for each direction is reported after
each BI.
53.3.5
Administration
Supervision of transmission faults and transmission quality can be
performed in different ways. With the help of parameters, the
supervision can be configured to meet a wide range of requirements.
The configuration parameters can only be changed when the AO DP is
in state "Disable". The parameters of interest are given below:
Table 182
Parameter
N1
N2
N3
N4
420 (485)
The configuration parameter N
Defines the threshold number (SES) for commence, and
cease, of CSES
Value range is 5-60
Default value is 10
The parameters P and Q
Used for defining unavailable state
Value range is 5-15 s
Default value is 10 s
The parameters N1 and N4
Define the threshold numbers for ES and SES. Value
range and default values are listed below:
Parameters N1-N4
Value
Range
805
1-1000
-
-
28
1-100
The configuration parameter T
The parameter T defines the time interval for ERATE
supervision
Value range is 1-5 s
Default value is 2 s
The configuration parameter AFT
The configuration parameter AFT defines the Alarm
Filtering Time for all the fault supervision functions
Value range is 50-5000 ms
Default value is 125 ms
© Ericsson Radio Systems AB
— All Rights Reserved —
Description (number of...)
CRC-4 errors for SES and E-bits equal to "0"
Not used
Not used
Frame errors for SES
EN/LZT 720 0008
P2A
2001-11-28

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rbs 2206

Table of Contents