15.2.4
Indicators
There are three indicators located on the front panel:
Table 116
Indicator
Fault
Operational
EPC bus fault
15.2.5
Input Data
Table 117
Nominal input voltage
Permitted variation input voltage
Input Current
Inrush current
Efficiency
Non-destructive voltage
Max. power consumption
Max. heat generation
15.2.6
Output Data
Table 118
Nominal output voltage
Factory set value
Voltage range
Output power
Output current at 27.2
Output current at short circuit
EN/LZT 720 0008
P2A
2001-11-28
input -48/-60 V DC
output +27.2 V DC
EPC Bus (Opto)
The PSU has no backplane connections.
Input data
Output data
© Ericsson Radio Systems AB
— All Rights Reserved —
Unit Description, PSU 1200 W
Colour
Red
Green
Yellow
(-48) - (-60) V DC
(-39) - (-72) V DC
< 36 A
< 200 A
> 85%
0 - (-75) V DC
1411 W
211 W
+24 V DC
+27.2 ±0.1 V DC
22.0 - 29.0 V DC
1200 W
44.1 A
< 60 A
193 (485)