Table 10
Environmental Parameters
Vibration sinus:
Vibration random:
Shock:
1)
Safe function
2)
Non destruction
3)
These requirements belong to 'Safe function' with the exemption:
performance of the RBS shall be verified as 'no loss of calls'
Seismic Exposure
The complete equipped RBS shall be tested for seismic exposure.
Deviations shall be reported.
Safe function during seismic exposure. Deviations shall be reported.
EN/LZT 720 0008
P2A
2001-11-28
Unit
displacement
mm
acceleration
m/s²
frequency
Hz
no. of sweep cycles
no. of test directions
testing method
2
ASD
m
2
ASD
m
acceleration
m/s²
acceleration
m/s²
frequency
Hz
testing method
peak acceleration
m/s²
duration
ms
pulse shape
no. of shock pulses
no. of test directions
testing method
© Ericsson Radio Systems AB
— All Rights Reserved —
Environmental Capabilities
0.6
2-9
3
/s
3
/s
<100 kg
250
6
Value
2
9 -200
5
3
IEC 68-2-6
1)
0.1
2)
0.2
1)
3.8
2)
5.4
2-200
IEC
68-2-64
>100 kg
3)
100
6
half sine
500 per
direction
6
IEC
68-2-27
29 (485)