to the compute node with fiber optic cables. The device must have at least one
functioning RAID canister, one functioning power supply, and one functioning fan.
The following figure shows the Primary Storage Shelf rear panel.
Figure 1-9
2
3
4
5
Note: Latches that let you remove the canisters are circled in red.
Primary Storage Shelf rear panel components
Table 1-5
Number
1
2 and 5
3 and 4
Each RAID canister has a set of LEDs which are defined in the following figure.
The table describes the LEDs functions and colors. The LEDs labeled '1' track the
data rate of the link. If both are off, the link is inactive, and if both are on, the data
rate is 8 Gb per second. If only one LED is on, the LED on the left indicates a 2
Gb/s data rate, and the one on the right indicates a 4 Gb/s data rate. The canister
also displays the ID of the Primary Storage Shelf, which is set to '99'.
Figure 1-10
1 1
1
About the Velocity 7330 Appliance Primary Storage Shelf
Primary Storage Shelf rear panel
1
Description
Fan canisters
Power canisters
RAID controller canisters
RAID canister LEDs
1
4 5 6 7 8
9
Hardware overview
2 3
1
1
1
1
16