HP FlexFabric 5950 series Configuration Manual page 169

Hide thumbs Also See for FlexFabric 5950 series:
Table of Contents

Advertisement

4.
Configure admin-scoped zone boundaries:
# On Switch B, configure VLAN-interface 102 and VLAN-interface 103 as the boundaries of
admin-scoped zone 1.
[SwitchB] interface vlan-interface 102
[SwitchB-Vlan-interface102] multicast boundary 239.0.0.0 8
[SwitchB-Vlan-interface102] quit
[SwitchB] interface vlan-interface 103
[SwitchB-Vlan-interface103] multicast boundary 239.0.0.0 8
[SwitchB-Vlan-interface103] quit
# On Switch C, configure VLAN-interface 103 and VLAN-interface 106 as the boundaries of
admin-scoped zone 2.
<SwitchC> system-view
[SwitchC] interface vlan-interface 103
[SwitchC-Vlan-interface103] multicast boundary 239.0.0.0 8
[SwitchC-Vlan-interface103] quit
[SwitchC] interface vlan-interface 106
[SwitchC-Vlan-interface106] multicast boundary 239.0.0.0 8
[SwitchC-Vlan-interface106] quit
# On Switch D, configure VLAN-interface 107 as the boundary of admin-scoped zone 2.
<SwitchD> system-view
[SwitchD] interface vlan-interface 107
[SwitchD-Vlan-interface107] multicast boundary 239.0.0.0 8
[SwitchD-Vlan-interface107] quit
5.
Configure C-BSRs and C-RPs:
# On Switch B, configure the service scope of RP advertisements.
[SwitchB] acl basic 2001
[SwitchB-acl-ipv4-basic-2001] rule permit source 239.0.0.0 0.255.255.255
[SwitchB-acl-ipv4-basic-2001] quit
# Configure VLAN-interface 101 as a C-BSR and a C-RP for admin-scoped zone 1.
[SwitchB] pim
[SwitchB-pim] c-bsr 10.110.1.2 scope 239.0.0.0 8
[SwitchB-pim] c-rp 10.110.1.2 group-policy 2001
[SwitchB-pim] quit
# On Switch D, configure the service scope of RP advertisements.
[SwitchD] acl basic 2001
[SwitchD-acl-ipv4-basic-2001] rule permit source 239.0.0.0 0.255.255.255
[SwitchD-acl-ipv4-basic-2001] quit
# Configure VLAN-interface 105 as a C-BSR and a C-RP for admin-scoped zone 2.
[SwitchD] pim
[SwitchD-pim] c-bsr 10.110.5.2 scope 239.0.0.0 8
[SwitchD-pim] c-rp 10.110.5.2 group-policy 2001
[SwitchD-pim] quit
# On Switch F, configure VLAN-interface 109 as a C-BSR and a C-RP for the global-scoped
zone.
<SwitchF> system-view
[SwitchF] pim
[SwitchF-pim] c-bsr 10.110.9.1
[SwitchF-pim] c-rp 10.110.9.1
159

Advertisement

Table of Contents
loading

Table of Contents