3.Troubleshooting
Code
0-06
The other terminal did not reply to DCS
0-07
No post-message response from the
other party after a page was sent
0-08
The other party sent RTN or PIN after
receiving a page, because there were too
many errors
0-14
Non-standard post message response
code received
0-15
The other terminal is not capable of
40
Meaning
Suggested Cause/Action
Check the connection.
Try adjusting the TX level and/or cable equalizer
settings.
Replace the FCU.
The other party may be defective or incompatible; try
sending to another machine.
Check for line problems.
Reference:
See error code 0-04.
Check the connection.
Replace the FCU.
The other party is out of paper or has a paper jam.
The other party may have disconnected the call.
Check for a bad line.
The other machine may be defective. Try sending to
another machine.
Check the connection.
Replace the FCU.
The other party may have a paper jam, or run out of
paper or memory space.
Try adjusting the TX level and/or cable equalizer
settings.
The other party may have a defective modem/FCU; try
sending to another machine.
Check for line problems and noise.
Reference:
TX level: NCU Parameter 01 (PSTN)
Cable equalizer: G3 Switch 07 (PSTN)
Dedicated TX parameters in Service Program Mode
Incompatible or defective remote terminal; try sending
to another machine.
Noisy line; resend.
Try adjusting the TX level and/or cable equalizer
settings.
Replace the FCU.
Reference:
See error code 0-08.
The other party is unable to accepting the following