Message
No Net Found
xxxxxxxxxxxx yy
No Reg Domain
No PBX
No SW found
Server Busy
Service
Unavailable.
Restarting ...
Storing Config
System Busy
yyy.yyy.yyy.yyy
1725-36030-001_B.doc
Description
AP does not support appropriate data
rates.
Out of range.
Incorrect Security settings.
x...x = AP MAC address
yy = AP signal strength
Handset cannot find a suitable access
point; displays MAC and signal strength
of "best" non-suitable AP found.
Regulatory Domain not set.
No communication with host telephone
system.
A required software component has not
been identified.
Handset is attempting to download from
a Download Master that is busy
downloading other handsets and
refusing additional downloads.
An error has caused the handset to lose
the call. It is now making its best effort to
restart and return to standby mode.
Handset is storing changes to handset
configuration.
y...y = SVP Server/Telephony Gateway
IP Address
Gateway or SVP server has reached call
capacity; displays IP address of
Gateway/SVP Server.
Action
Check the AP configuration against
Configuration Note for AP.
Try getting closer to an AP. Check to
see if other handsets are working
within the same range of an AP. If
so, check the SSID of this handset.
Verify that all the security settings in
the WT match those in the APs.
Check AP and handset network
settings such as SSID, Security, Reg
domain and Tx power. Ensure APs
are configured per Configuration
Note. Try Site Survey mode to
determine more specific cause.
Configure the Regulatory Domain of
the handset.
Displays before the system has
synchronized ports with the host
telephone system. Should disappear
when the ports are correctly wired
and programmed.
Make sure the proper PBX switch
has been selected within the
SpectraLink 8000 Telephony
Gateway.
Check that the correct software has
been downloaded and is available.
None. The handset will automatically
retry the download every few
seconds.
Occurs during Restart on Error
mode. The handset is attempting to
register with the PBX and resume
normal operation. Error details may
be available through the syslog
server and by download with the
Handset Administration Tool.
None. Informational only. The
handset may display this briefly
following a configuration change or
software download.
All call paths are in use. Try the call
again in a few minutes.