H3C S9500E Series Configuration Manual page 204

Routing switches
Hide thumbs Also See for S9500E Series:
Table of Contents

Advertisement

After shutting down the uplink interface on Switch A, display detailed information about VRRP
group 1 on Switch A.
[SwitchA-Vlan-interface3] display vrrp verbose
IPv4 Standby Information:
Run Mode
Run Method
Total number of virtual routers : 1
Interface Vlan-interface2
VRID
Admin Status
Config Pri
Preempt Mode
Auth Type
Virtual IP
Master IP
VRRP Track Information:
Track Object
After shutting down the uplink interface on Switch A, display detailed information about VRRP
group 1 on Switch B.
[SwitchB-Vlan-interface2] display vrrp verbose
IPv4 Standby Information:
Run Mode
Run Method
Total number of virtual routers : 1
Interface Vlan-interface2
VRID
Admin Status
Config Pri
Preempt Mode
Auth Type
Virtual IP
Virtual MAC
Master IP
The output information shows that when the uplink interface on Switch A is shut down, the priority
of Switch A decreases to 80. Switch A becomes the backup, and Switch B becomes the master.
Packets from Host A to Host B are forwarded through Switch B.
: Standard
: Virtual MAC
: 1
: Up
: 110
: Yes
: None
: 10.1.1.10
: 10.1.1.2
: 1
: Standard
: Virtual MAC
: 1
: Up
: 100
: Yes
: None
: 10.1.1.10
: 0000-5e00-0101
: 10.1.1.2
204
Adver Timer
: 1
State
: Backup
Running Pri
: 80
Delay Time
: 0
State : Negative
Adver Timer
: 1
State
: Master
Running Pri
: 100
Delay Time
: 0
Pri Reduced : 30

Advertisement

Table of Contents
loading

Table of Contents