[SwitchA] oam errored-frame threshold 10
Configure Switch B
2.
Configure GigabitEthernet 4/0/1 to operate in active Ethernet OAM mode (the default) and
enable Ethernet OAM for it.
<SwitchB> system-view
[SwitchB] interface gigabitethernet 4/0/1
[SwitchB-GigabitEthernet4/0/1] oam mode active
[SwitchB-GigabitEthernet4/0/1] oam enable
[SwitchB-GigabitEthernet4/0/1] quit
Verify the configuration
3.
Display the global Ethernet OAM configuration information on Switch A.
[SwitchA] display oam configuration
Configuration of the link event window/threshold :
--------------------------------------------------------------------------
Errored-symbol Event period(in seconds)
Errored-symbol Event threshold
Errored-frame Event period(in seconds)
Errored-frame Event threshold
Errored-frame-period Event period(in ms)
Errored-frame-period Event threshold
Errored-frame-seconds Event period(in seconds)
Errored-frame-seconds Event threshold
According to the above output information, the detection period of errored frame events is 20
seconds, the detection threshold is 10 seconds, and all the other parameters use the default
values.
Display the statistics of Ethernet OAM critical link events on all the ports of Switch A.
[SwitchA] display oam critical-event
Port
: GigabitEthernet4/0/1
Link Status : Up
Event statistic :
-------------------------------------------------------------------------
Link Fault
:0
According to the above output information, no critical link event occurred on the link between
Switch A and Switch B.
Display Ethernet OAM link event statistics of the remote end of Switch B.
[SwitchB] display oam link-event remote
Port :GigabitEthernet4/0/1
Link Status :Up
OAMRemoteErrFrameEvent : (ms = milliseconds)
Dying Gasp
: 0
29
:
1
:
1
:
20
:
10
:
1000
:
1
:
60
:
1
Critical Event
: 0