[SwitchB] ipv6
[SwitchB] vlan 2
[SwitchB-vlan2] port Gigabitethernet 3/0/5
[SwitchB-vlan2] quit
[SwitchB] interface vlan-interface 2
[SwitchB-Vlan-interface2] ipv6 address fe80::2 link-local
[SwitchB-Vlan-interface2] ipv6 address 1::2 64
Create a VRRP group 1 and set its virtual IPv6 addresses to FE80::10.
[SwitchB-Vlan-interface2] vrrp ipv6 vrid 1 virtual-ip fe80::10 link-local
Configure Switch B to work in the preemptive mode, with the preemption delay set to 5 seconds.
[SwitchB-Vlan-interface2] vrrp ipv6 vrid 1 preempt-mode timer delay 5
Enable Switch B to send RA messages.
[SwitchB-Vlan-interface2] vrrp ipv6 vrid 1 preempt-mode timer delay 5
Verify the configuration
3.
After the configuration, Host B can be pinged through on Host A. You can use the display vrrp
ipv6 verbose command to verify the configuration.
Display detailed information of VRRP group 1 on Switch A.
[SwitchA-Vlan-interface2] display vrrp ipv6 verbose
IPv6 Standby Information:
Run Mode
Run Method
Total number of virtual routers : 1
Interface Vlan-interface2
VRID
Admin Status
Config Pri
Preempt Mode
Auth Type
Virtual IP
Virtual MAC
Master IP
Display detailed information of VRRP group 1 on Switch B.
[SwitchB-Vlan-interface2] display vrrp ipv6 verbose
IPv6 Standby Information:
Run Mode
Run Method
Total number of virtual routers : 1
Interface Vlan-interface2
: Standard
: Virtual MAC
: 1
: Up
: 110
: Yes
: None
: FE80::10
1::10
: 0000-5e00-0201
: FE80::1
: Standard
: Virtual MAC
149
Adver Timer
: 100
State
: Master
Running Pri
: 110
Delay Time
: 5