Parameters That Can Be Set - Omron DST1-ID12SL-1 Operation Manual

Dst1 series safety i/o terminals
Hide thumbs Also See for DST1-ID12SL-1:
Table of Contents

Advertisement

Logic Functions
1-5-3

Parameters That Can Be Set

Data That Can Be Set for Input Condition Signals
Name
Input condi-
tion signal
Data That Can Be Set for Reset Signals
Reset signal
18
Option
Remote I/O
Input 0 to Input 5
The following data is used for remote I/O data. For details on remote I/O allo-
cations, refer to 3-2-4 I/O Assembly Data.
Bit 7
Bit 6
Reserved for
Input
system.
condition
signal
No. 5
Example 1: IN0 and IN1 Used in Single Channel Mode
IN0 input condition signal:
IN1 input condition signal:
Example 2: IN0 and IN1 Used in Dual Channel Mode
IN0 input condition signal:
IN1 input condition signal:
Name
Option
Remote I/O
Low-High-
Low
Remote I/O
Rising Edge
IN6 Low-
High-Low
IN6 Rising
Edge
IN7 Low-
High-Low
IN7 Rising
Edge
The following data is used for remote I/O data. For details on remote I/O allo-
cation, refer to 3-2-4 I/O Assembly Data.
Bit 7
Bit 6
Reserved for system. Reset sig-
nal
No.5
Example 1: IN0 and IN1 Used in Single Channel Mode
IN0 reset signal: Bit 0 reset signal 0 (0/1) is used.
IN1 reset signal: Bit 1 reset signal 1 is used.
Example 2: IN0 and IN1 Used in Dual Channel Mode
IN0 reset signal: Bit 0 reset signal 0 (0/1) is used.
IN1 reset signal: Setting not required.
Remote safety I/O data (received from Safety Master through the
network)
Safety input terminals IN0 to IN5
Bit 5
Bit 4
Bit 3
Input
Input
condition
condition
signal
signal
No. 4 (4/5)
No. 3
Remote safety I/O data (received from Safety Master or Standard
Master through the network) used for a Low-high-Low reset.
Remote safety I/O data (received from Safety Master or Standard
Master through the network) used for a Rising Edge reset.
The IN6 terminal is used for a Low-High-Low reset.
The IN6 terminal is used for a Rising Edge reset.
The IN7 terminal is used for a Low-High-Low reset.
The IN7 terminal is used for a Rising Edge reset.
Bit 5
Bit 4
Bit 3
Reset sig-
Reset sig-
nal
nal
No.4 (4/5)
No.3
Section 1-5
Setting range
Bit 2
Bit 1
Input
Input
condition
condition
signal
signal
No. 2 (2/3)
No. 1
Bit 0 input condition signal 0 (0/1)
is used.
Bit 1 input condition signal 1 is used.
Bit 0 input condition signal 0 (0/1)
is used.
Not Used.
Setting range
Bit 2
Bit 1
Reset sig-
Reset sig-
nal
nal
No.2 (2/3)
No.1
Bit 0
Input
condition
signal
No. 0 (0/1)
Bit 0
Reset sig-
nal
No.0 (0/1)