Figure 51: Releasing Spine Ejector Handles - Mellanox Technologies Switch-IB User Manual

324-port edr infiniband switch-ib series switch platform hardware
Table of Contents

Advertisement

Extract the spine module according to the procedure in
Step 2.
#1 or #2"
Extracting Spine Modules Except #1 or #2
Run the shutdown command no power enable <module>
Step 1.
example, run:
switch [master] (config) # no power enable S06
Push the ejector handles in the direction of the red arrows in
Step 2.
wards to unlock the ejectors from the chassis.
Open the ejectors until they are at a 45 degree angle from the module.
Step 3.
Pull out the module halfway through the guiding rails using both ejectors.
Step 4.
Re-lock the ejector handles.
Step 5.
Hold the body of the module on both sides and remove it from the chassis.
Step 6.
2.7.3.2 Inserting a Spine Module
When hot-swapping any of the units, it is necessary to wait 1 minute after removing
the defective part before inserting the new part. This is necessary so that the manage-
ment module will start a new cycle checking through the leafs and spines for the FW
versions.
To insert a spine module:
Check for foreign objects in or mechanical damage to the chassis spine slots.
Step 1.
Check back signal connectors' integrity. Look for any broken signal dividers or any devia-
Step 2.
tions from the pass criteria shown in
Mellanox Technologies
starting with Step 2 (without running the shutdown command).
Traffic loss and errors in the log may be experienced momentarily.

Figure 51: Releasing Spine Ejector Handles

Push in this direc-
Do not use the fan FRU handle to extract the spine module.
"Extracting Spine Modules Except
.