Section 3: HART commissioning
April 2014
Figure 3-5. 3144P Device Dashboard HART 7- Configure
3144P HART Revision 7
Menu Trees - Configure
Overview
Configure
Service Tools
Key
Bold = Menu Title
Underline = Method
36
Guided Setup
1. Configure Sensors
2. Calibrate Sensors
3. Configure Device
4. Configure Display
5. Config Hot Backup
6. Config Drift Alert
Configure
7. Diagnostics Suite
1. Guided Setup
2. Manual Setup
Manual Setup
1. Sensor 1
2. Sensor 2
3. Calculated Output
4. Diagnostics
5. Analog Output
6. Display
7. Device
8. HART
9. Security
Security
1. Security Switch
2. HART Lock
Burst Mode Config.
1. Burst Message 1
2. Message 1 Content
3. 1st and Trigger Value
4. Second Variable
5. Third Variable
6. Fourth Variable
7. Configure Additional Messages
Sensor 1
1.
Sensor 1 Temp
2.
Sensor 1 Status
3.
Sensor 1 Type
4.
Sensor 1 Connection
SensorMatching-CVD
5.
Engineering Units
1. RO Value
6.
2-Wire Offset
2. A Value
7.
Damping
3. B Value
8.
Serial Number
4. C Value
9.
Upper Sensor Limit
5. Set CVD Coefficients
10. Lower Sensor Limit
6. View CVD a,b,d
11. SensorMatching-CVD
Sensor 2
1.
Sensor 2 Temp
2.
Sensor 2 Status
3.
Sensor 2 Type
4.
Sensor 2 Connection
SensorMatching-CVD
5.
Engineering Units
1. RO Value
6.
2-Wire Offset
2. A Value
7.
Damping
3. B Value
8.
Serial Number
4. C Value
9.
Upper Sensor Limit
5. Set CVD Coefficients
10. Lower Sensor Limit
6. View CVD a,b,d
11. SensorMatching-CVD
Differential Temperature
1. Differential Value
2. Units
3. Damping
Calculated Output
First Good Temperature
1. Differential Temperature
1. First Good Value
2. First Good Temperature
2. Units
3. Average Temperature
3. Damping
Average Temperature
1. Average Value
2. Units
3. Damping
Diagnostics
1. Hot Backup
Hot Backup
2. Sensor Drift Alert
1. Hot Backup Mode
3. Sensor and Process
2. Primary Variable
Diagnostics
3. Config Hot Backup
4. Reset Hot Backup
Sensor and Process
Sensor Drift Alert
Diagnostics
1. Mode
1. TC Diag Mode Snr 1
2. Threshold
2. Drift Alert Threshold
3. Damping
3. Drift Alert Damping
4. Drift Alert Eng. Units
4. Drift Alert Eng. Units
5. Config. Drift Alert
5. Configure Drift Alert
PV Configuration
1. Primary Variable is
2. Upper Range Value
Analog Output
3. Lower Range Value
1. Primary Variable
4. Minimum Span
2. Param.
3. Analog Output Value
4. Percent of Range
5. PV Configuration
Display
1. Variables Displayed
2. Decimal Places
3. Bar Graph
Device Information
1. Tag
2. Long Tag
Device
2. Date
1. Device Information
3. Descriptor
2. Security Switch
4. Message
3. Terminal Temp Units
5. Final Assembly No
4. Open Sensor Holdoff
5. Noise Rejection
Noise Rejection
6. Processor Reset
1. AC Power Filter
2. Transient Filter
Variable Mapping
HART
1. Primary Variable is
1. Polling Address
2. Second Variable is
2. Universal
3. Third Variable is
3. Change HART Rev
4. Fourth Variable is
4. Burst Mode option
5. Re-map Variables
5. Burst Mode Config.
6. Variable Mapping
Reference Manual
00809-0100-4021, Rev GC
HART® commissioning