Quick Start Guide March 2020 Contents About this guide...........................3 Mount the transmitter........................5 Wire and apply power........................7 Verify tagging..........................12 Product certifications......................... 16 Rosemount 3144P...
March 2020 Quick Start Guide About this guide This guide provides basic guidelines for installing the Rosemount 3144P Transmitter. It does not provide instructions for detailed configuration, diagnostics, maintenance, service, troubleshooting, Explosion-proof, Flameproof, or intrinsically safe (I.S.) installations. Refer to the Rosemount...
Page 4
Physical security is an important part of any security program and fundamental to protecting your system. Restrict physical access by unauthorized personnel to protect end users’ assets. This is true for all systems used within the facility. Rosemount 3144P...
March 2020 Quick Start Guide Mount the transmitter Mount the transmitter at a high point in the conduit run to prevent moisture from draining into the transmitter housing. Typical North American installation Figure 2-1: Typical Direct-Mounted Configuration A. Thermowell B. Extension (nipple) C.
Page 6
9. Insert shielded cable leads through the cable entries into the connection head/transmitter. Connect and tighten cable glands. 10. Connect the shielded cable leads to the connection head terminals (located inside the connection head) and to the sensor wiring terminals (located inside the transmitter housing). Rosemount 3144P...
Emerson provides 4-wire sensors for all single-element RTDs. You can use these RTDs in 3- wire configurations by leaving the unneeded leads disconnected and insulated with electrical tape. Transmitter must be configured for a 3-wire RTD in order to recognize an RTD with a compensation loop.
Page 8
2. Connect power to the power terminal. The terminals are polarity insensitive. 3. Tighten the terminal screws. 4. Reattach and tighten the cover. WARNING Enclosure Enclosure covers must be fully engaged to meet explosion-proof requirements. 5. Apply power. Rosemount 3144P...
Page 9
1 (the most common). Ground the transmitter: option 1 Emerson recommends this option for ungrounded transmitter housing. Procedure 1. Connect signal wiring shield to the sensor wiring shield.
Page 10
3. Ground signal wiring shield at the power supply end. A. Sensor wire B. Transmitter C. Shield ground point 3.3.2 Ground thermocouple inputs Procedure 1. Ground sensor wiring shield at the sensor. Rosemount 3144P...
Page 11
March 2020 Quick Start Guide 2. Ensure the sensor wiring and signal wiring shields are electrically isolated from the transmitter housing and other grounded fixtures. 3. Ground signal wiring shield at the power supply end. A. Sensor wire B. Transmitter C.
Fieldbus host or configuration tool has a different way of OUNDATION displaying and performing configurations. Some use Device Descriptions (DD) or DD methods for configuration and to display data consistently across platforms. There is no requirement that a host or configuration tool support these features. Rosemount 3144P...
Page 13
The following is the minimum configuration requirement for a temperature measurement. This guide is designed for systems not using DD methods. For a complete list of parameters and configuration information, refer to the Rosemount 3144P Temperature Transmitter Reference Manual. Transducer function block This block contains temperature measurement data for the sensors and the terminal temperature.
Page 14
Set desired measurement range and units. Units must be one of the following: • • Ohms • °C • °F • °R • OUT_SCALE For “DIRECT” L_TYPE, set OUT_SCALE to match XD_SCALE HI_HI_LIM Process alarms. HI_LIM Must be within the range defined by “OUT_SCALE” LO_LIM LO_LO_LIM Rosemount 3144P...
Page 15
March 2020 Quick Start Guide Note To make changes to the AI block, set the BLOCK_MODE (TARGET) to OOS (out of service). After making the changes, return the BLOCK_MODE TARGET to AUTO. 4.2.2 Set switches The security and simulate switches are located on the top center of the electronics module.
A copy of the EU Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EU Declaration of Conformity can be found at Emerson.com/Rosemount. Ordinary location certification As standard, the transmitter has been examined and tested to determine...
Page 17
March 2020 Quick Start Guide 5.3.3 I6 CSA Intrinisic Safety and Division 2 Certificate 1242650 Standards CAN/CSA C22.2 No. 0-M91 (R2001), CAN/CSA-C22.2 No. 94- M91, CSA Std C22.2 No. 142-M1987, CAN/CSA-C22.2 No. 157-92, CSA Std C22.2 No. 213-M1987 Markings Intrinsically Safe for Class I Groups A, B, C, D; Class II, Groups E, F, G;...
Page 18
500 V insulation test. This must be taken into account during installation. 2. The enclosure may be made from aluminum alloy with a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion when located in Zone 0. Rosemount 3144P...
Page 19
March 2020 Quick Start Guide 5.4.3 N1 ATEX Type n Certificate BAS01ATEX3432X [HART]; Baseefa03ATEX0709X [Fieldbus] Standards EN IEC 60079-0:2018, EN 60079-15:2010 Markings HART: II 3 G Ex nA IIC T5/T6 Gc; T6(-40 °C ≤ T ≤ +50 °C), T5(-40 °C ≤ T ≤...
Page 20
IEC 60079-0:2011 and IEC 60079-31:2013 Markings Ex tb IIIC T130 °C Db, (-40 °C ≤ T ≤ +70 °C); IP66 Process temperature limits for process temperatures. Specific conditions of use (X): 1. See certificate for ambient temperature range. Rosemount 3144P...
Page 21
March 2020 Quick Start Guide 2. The non-metallic label may store an electrostatic charge and become a source of ignition in Group III environments. 3. Guard the LCD display cover against impact energies greater than four joules. 4. Flameproof joints are not intended for repair. 5.
Page 22
500 V electrical strength test as defined in ABNT NBR IEC60079-11. This must be taken into account during installation. 2. The enclosure may be made from aluminum alloy with a protective polyurethane paint finish; however, care should be taken to protect it Rosemount 3144P...
Page 23
March 2020 Quick Start Guide from impact and abrasion when located in areas that require EPL Ga (Zone 0). INMETRO Intrinsic Safety [Fieldbus/FISCO] Certificate UL-BR 15.0030X Standards ABNT NBR IEC 60079-0:2013, ABNT NBR IEC 60079-11:2013 Markings Ex ia IIC T4 Ga (-60 °C < T <...
Page 24
GB3836.4-2010 标准中第 6.3.12 条规定的 500V 交流有效值试验电压的介电强度试验 产品使用注意事项 • 1. 产品温度组别与使用环境温度范围的关系: 输出 温度组别 环境温度 ® HART -60 °C ≤ T ≤ +50 °C -60 °C ≤ T ≤ +75 °C Fieldbus -60 °C ≤ T ≤ +60 °C 2. 本安电气参数: Rosemount 3144P...
Page 26
500V 耐压试验,安装时必须考虑在内 产品使用注意事项 • 1. 产品使用环境温度为: -40 °C ≤ T ≤ +70 °C (Fieldbus) HART Table 5-4: HART 温度组别 环境温度 -40 °C ≤ T ≤ +75 °C -40 °C ≤ T ≤ +50 °C 2. 输入电压:32 Vdc(Fieldbus),42.4 Vdc(HART) Rosemount 3144P...
Page 28
Special Condition for Safe Use (X): 1. See certificate for special conditions. 5.10.2 IP Korea Intrinsic Safety Certificate 09-KB4BO-0028X Markings Ex ia IIC T6/T5; T6(-60 °C ≤ T ≤ +50 °C), T5(-60 °C ≤ T ≤ +75 °C) Rosemount 3144P...
Page 29
March 2020 Quick Start Guide Special Condition for Safe Use (X): 1. See certificate for special conditions. 5.11 Combinations Combination of E1, I1, N1, and ND Combination of E2 and I2 Combination of E5 and I5 Combination of K5, I6, and K6 Combination of EP and IP 5.12 Tables...
Page 30
Capacitance C (nF) 5 Inductance L (mH) 5.13 Additional certifications SBS American Bureau of Shipping (ABS) Type Approval Certificate 16-HS1488352-PDA Intended use Measurement of temperature for marine and offshore applications SBV Bureau Veritas (BV) Type Approval Certificate 23154 Rosemount 3144P...
Page 31
March 2020 Quick Start Guide Requirements Bureau Veritas Rules for the Classification of Steel Ships Application Class notations: AUT-UMS, AUT-CCS, AUT-PORT and AUT- IMS; Temperature transmitter type 3144P cannot be installed on diesel engines. SDN Det Norske Veritas (DNV) Type Approval Certificate TAA00001JK Intended use Det Norske Veritas’...
Page 32
Quick Start Guide March 2020 5.14 Declaration of conformity Rosemount 3144P...
Page 33
March 2020 Quick Start Guide Quick Start Guide...
Page 34
Quick Start Guide March 2020 Rosemount 3144P...
Page 35
March 2020 Quick Start Guide 5.15 China RoHS Quick Start Guide...
Page 36
The Emerson logo is a Twitter.com/Rosemount_News trademark and service mark of Emerson Electric Facebook.com/Rosemount Co. Rosemount is a mark of one of the Emerson Youtube.com/user/ family of companies. All other marks are the RosemountMeasurement property of their respective owners.