Section 3: HART commissioning
April 2014
Figure 3-3. 3144P Device Dashboard HART 5- Service Tools
3144P HART Revision 5
Menu Trees – Service Tools
Overview
Configure
Service Tools
34
Key
Bold = Menu Title
Underline = Method
Service Tools
1. Alerts
2. Variables
3. Trends
4. Maintenance
5. Simulate
Maintenance
1. Thermocouple Diag Snsr 1
2. Thermocouple Diag Snsr 2
3. Min/Max Tracking
4. Sensor Calibration
5. Analog Calibration
Simulate
1. Perform Loop Test
Good
1. No Active Alerts
Failed
1. Invalid Configuration
2. Electronics Failure
3. Calibration Error
Active Alerts
4. Sensor Drift Alert Active
1. Good (only if no alerts)
5. Sensor 1 Open
2. Failed (Fix Now)
6. Sensor 2 Open
3. Advisory
7. Sensor 1 Short
4. Maintenance (Fix Soon)
8. Sensor 2 Short
9. Terminal Temperature Failure
10. Device Malfunction
Advisory
1. Calibration Error
2. Configuration Changed
Maintenance
1. Hot Backup Active
2. Sensor Drift Alert Active
3. Sensor 1 TC Degraded
4. Sensor 2 TC Degraded
5 Sensor 1 Excess EMF
6. Sensor 2 Excess EMF
7. Sensor 1 Out of Operating Range
8. Sensor 2 Out of Operating Range
9. Terminal Temperature Out of
Range
10. Primary Out of Limits
11. Analog Output Saturated
12. Analog Output Fixed
13. Non-Primary Variable out of
Limits
Primary Variable
1. Primary Variable
2. Parameter
3. PV Gauge
Second Variable
1. Second Variable
Variables
2. Parameter
1. Variable Summary
3. SV Gauge
2. Primary Variable
3. Secondary Variable
Third Variable
4. Third Variable
1. Third Variable
5. Fourth Variable
2. Parameter
6. Analog Output
3. TV Gauge
Fourth Variable
1. Fourth Variable
2. Parameter
3. FV Gauge
Analog Output
1. Analog Output Value
2. AO Gauge
Trends
Thermocouple Diag Sensor X
1. Sensor 1 Temperature
1. Resistance
2. Sensor 2 Temperature
2. Sensor X Status
3. Differential Temperature
3. Threshold Exceeded
4. Average Temperature
4. TC Diag Config
5. Terminal Temperature
6. First Good Temperature
TC Diag Config
1. TC Diag Mode Snsr X
2. Trigger Level
3. Baseline resistance
4. Reset Baseline
Min/Max Tracking
1. Min/Max Mode
2. Reset All Min/Max Values
3. Parameter 1
4. Parameter 2
5. Parameter 3
Sensor Calibration
6. Parameter 4
1. Calibrate Sensors
2. Restore Factory Cal
3. Sensor 1 Lower Cal
Parameter X
4. Sensor 1 Upper Cal
1. Parameter X
5. Sensor 2 Lower Cal
2. Maximum Value
6. Sensor 2 Upper Cal
3. Minimum Value
7. Active Calibrator
4. Reset Parameter X
Analog Calibration
1. Analog Trim
2. Scaled Trim
Reference Manual
00809-0100-4021, Rev GC
HART® commissioning

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3144p

Table of Contents