TARGETS MENU

7.1.6 Security

COMMANDS  SECURITY
 SECURITY

With the CyberSentry option, this setting is available to enable or disable the following commands.
ADMINISTRATOR LOGOFF
ENGINEER LOGOFF
OPERATOR LOGOFF
CLEAR SECURITY DATA
operands associated with the self-tests.
7.2 Targets menu
7
A target enables the EnerVista UR Setup software to monitor automatically and display the status of any active target
messages of all the devices inserted into that site.
Each G60 element with a TARGET setting has a target message that when activated by its element is displayed in
sequence with any other currently active target messages in the
and Digital Element 48 target settings are active and so have their targets displayed. The down arrow below the two
elements indicates that there can be other active elements beyond these two.
For more information, see the description of target messages in the next section, and the Introduction to Elements section
in the Settings chapter for instructions on TARGET setting.
When no targets are active, the display reads

7.2.1 Target messages

When there are no active targets, the first target to become active causes the display to immediately default to that
message. If there are active targets and the user is navigating through other messages, and when the default message
timer times out (i.e. the keypad has not been used for a determined period of time), the display again defaults back to the
target message.
7-6
ADMINISTRATOR
LOGOFF: No
ENGINEER
LOGOFF: No
OPERATOR
LOGOFF: No
CLEAR SECURITY DATA:
No
— Selecting 'Yes' allows the Supervisor to forcefully logoff an administrator session.
— Selecting 'Yes' allows the Supervisor to forcefully logoff an engineer session.
— Selecting 'Yes' allows the Supervisor to forcefully logoff an operator session.
— Selecting 'Yes' allows the Supervisor to forcefully clear all the security logs and clears all the
TARGETS
PHASE TOC4
OP: A B -
DIGITAL ELEMENT 48:
LATCHED
NO ACTIVE TARGETS
Range: Yes, No
Range: Yes, No
Range: Yes, No
Range: Yes, No
Displayed only if targets for this element are active.
Example shown.
Displayed only if targets for this element are active.
Example shown.
menu. In the example shown, the Phase TOC4