B Troubleshooting; Problems Accessing The Management Interface; Table 36: Troubleshooting Chart - Edge-Core ECS4210-12P Web Management Manual

12/28-port gigabit ethernet layer 2 switch
Hide thumbs Also See for ECS4210-12P:
Table of Contents

Advertisement

B

Problems Accessing the Management Interface

Troubleshooting

Table 36: Troubleshooting Chart

Symptom
Cannot connect using
Telnet, web browser, or
SNMP software
Cannot connect using
Secure Shell
Cannot access the on-
board configuration
program via a serial port
connection
Forgot or lost the password
Action
Be sure the switch is powered up.
Check network cabling between the management station and the
switch.
Check that you have a valid network connection to the switch and
that the port you are using has not been disabled.
Be sure you have configured the VLAN interface through which the
management station is connected with a valid IP address, subnet
mask and default gateway.
Be sure the management station has an IP address in the same
subnet as the switch's IP interface to which it is connected.
If you are trying to connect to the switch via the IP address for a
tagged VLAN group, your management station, and the ports
connecting intermediate switches in the network, must be
configured with the appropriate tag.
If you cannot connect using Telnet, you may have exceeded the
maximum number of concurrent Telnet/SSH sessions permitted. Try
connecting again at a later time.
If you cannot connect using SSH, you may have exceeded the
maximum number of concurrent Telnet/SSH sessions permitted. Try
connecting again at a later time.
Be sure the control parameters for the SSH server are properly
configured on the switch, and that the SSH client software is
properly configured on the management station.
Be sure you have generated both an RSA and DSA public key on the
switch, exported this key to the SSH client, and enabled SSH service.
Be sure you have set up an account on the switch for each SSH user,
including user name, authentication level, and password.
Be sure you have imported the client's public key to the switch (if
public key authentication is used).
Be sure you have set the terminal emulator program to VT100
compatible, 8 data bits, 1 stop bit, no parity, and the baud rate set to
115200 bps).
Check that the null-modem serial cable conforms to the pin-out
connections provided in the Installation Guide.
Contact your local distributor.