Configuring Link Timeout - Siemens RUGGEDCOM WIN5123 User Manual

Win v5.0
Hide thumbs Also See for RUGGEDCOM WIN5123:
Table of Contents

Advertisement

RUGGEDCOM WIN
User Guide
Figure 30: System Functions Screen
2.
Configure the following parameter(s) as required:
Parameter
Link WatchDog
3.
Click Apply.
Section 4.2.2

Configuring Link Timeout

Link Timeout (min) is used to configure the number of minutes during which Link WatchDog will try to reset the
device before timing out. For more information about Link Watchdog, refer to
WatchDog"
.
To configure Link Timeout, do the following:
Navigate to Management » System Functions. The System Functions screen appears.
1.
Configuring Link Timeout
Description
Synopsis:   {Disabled, Smart, Always}
Disabled – the device never resets.
Smart (Default) – the device resets as follows: When the device is
in stopped mode, Link WatchDog will not reset the device. When
the device returns to start mode, the WatchDog timer will start
again from zero. When the device's channel scanner is empty,
WatchDog will not reset the device.
Always – the device always resets after the configured timeout
expires, when no RF link has been established.
Section 4.2.1, "Configuring Link
Chapter 4
System Administration
37