RUGGEDCOM WIN
User Guide
Parameter
Current SW Location
Primary SW Location
Primary CDC
Primary UV
Secondary SW Version
Secondary SW Location
Secondary CDC
Secondary UV
Configuration Changes Counter
Section 3.4.3

Loading the Primary Software Version

To load the Primary software image into the memory bank, do the following:
NOTE
Before performing this procedure, make sure the version in the Current Active Bank parameter is
displayed as Secondary.
1.
Navigate to Management » SW Upgrade. The SW Properties screen appears.
Loading the Primary Software Version
Description
Synopsis:   { 1, 2 }
Displays the number of the memory bank from which the device
software is running.
Synopsis:   { 1, 2 }
Displays the number of the current Primary memory bank.
Displays the filename of the CDC (Customer Defaults Configuration)
file in the Primary memory bank.
Displays the filename of the UV (Unique Value) file in the Primary
memory bank.
Displays the version number of the software in the Secondary
memory bank.
Displays the number of the memory bank selected as the Secondary
memory bank.
Displays the filename of the CDC (Customer Defaults Configuration)
file in the Secondary memory bank.
Displays the filename of the UV (Unique Value) configuration file in
the Primary memory bank.
Displays the number of changes made to configuration values on the
device. This value only includes changes to configuration values. It
does not include events, such as setting the primary software image
or uploading a file.