Viewing General Statistics - Siemens RUGGEDCOM WIN5123 User Manual

Win v5.0
Hide thumbs Also See for RUGGEDCOM WIN5123:
Table of Contents

Advertisement

RUGGEDCOM WIN
User Guide
Section 3.3.4, "Viewing and Clearing Service Flow Statistics"
Section 3.3.1

Viewing General Statistics

To view general statistics, navigate to Statistics. The General Statistics screen appears.
Figure 12: General Statistics Screen
The table provides the following information:
Parameter
CPE Name
MS ID
CPE Status
Link Up Time
Up Time
BS ID
Frequency [kHz]
Bandwidth
Current SW version
Current Authentication
Outer NAI
Viewing General Statistics
Description
Displays the name of the device. This name identifies the device on
the base station and in the base station management interface. The
name is set on the System Functions screen. For more information,
refer to
Section 4.1, "Configuring the Device Name"
Displays the mobile station MAC address.
Synopsis:   { Init, DL Synchronization, Handover DL acquisition, UL
Acquisition, Ranging, Handover ranging, Capabilities negotiation,
Authorization, Registration, DHCP, TOD, TFTP, Operational, Sleep,
IDLE, Aborted }
Displays the device's current status.
Displays the time since the device became operational.
Displays the time since the last device start-up.
Displays the base station ID.
Displays the device operating frequency, in kilohertz.
Synopsis:   { 3.5MHz, 5MHz, 7MHz, 10MHz }
Displays device bandwidth setting.
Displays the device's current software version number.
Synopsis:   { Null, EAP-TTLS, EAP-TLS }
Displays the device's current authentication mode.
Displays the outer network access identifier.
Chapter 3
Device Management
.
19