Supervisor Module LEDs

LED
FAB
IOM
Supervisor Module LEDs
LED
STATUS
ID
Cisco Nexus 7718 Switch Site Preparation and Hardware Installation Guide
192
Color
Status
Green
Fabric modules are all operational.
Amber
At least one fabric module LED is red.
Green
I/O modules are all operational.
Amber
At least one I/O module LED is red.
Color
Green
Red
Flashing red
Off
Flashing blue
Off
Status
All diagnostics pass. The module is operational (normal initialization
sequence).
Indicates one of the following:
• The module has detected a slot ID parity error and will not power
on or boot up.
• The module is not fully inserted and does not have a reliable
connection to the midplane.
• The diagnostic test has failed.
Indicates one of the following:
• The inlet air temperature of the system has exceeded the safe
operating temperature limits of the module (a major
environmental warning). The module has been shut down to
prevent permanent damage. The system will be shut down after
two minutes if this condition is not cleared.
• The module is resetting, and both ejector levers are out.
The module is not receiving power.
The operator has activated this LED to identify this module in the
chassis.
This module is not being identified.
LEDs