Cisco Nexus 7718 Hardware Installation Manual page 207

Table of Contents

Advertisement

LEDs
LED
Input 1
Input 2
(available
only on DC
power
supply
units)
Output
Fault
ID
OL-30453-01
Color
Status
Green
The AC, HVAC/HVDC, or DC input voltage is within the valid range.
Off
The AC, HVAC/HVDC, or DC input voltage is outside the valid range.
Green
The DC input voltage is within the valid range.
Off
The DC input voltage is outside the valid range.
Green
The AC or DC output power is within the valid range.
Off
The AC or DC output power is outside the valid range.
Off
The AC or DC output voltage and power supply unit tests are okay.
Flasing red
Self-diagnostic tests have failed or another power supply failure has occurred.
Flashing blue
The operator has activated this LED to identify this module in the chassis.
off
This module is not being identified.
Cisco Nexus 7718 Switch Site Preparation and Hardware Installation Guide