Installing or Replacing Modules, Fan Trays, and Power Supplies
2
c) After the connectors are free of the chassis connections, pull whole fan tray off the chassis.
d) Set the fan tray down on one of its covered sides only on an antistatic pad or inside an antistatic bag.
Caution
Step 2
If you need to open a fabric slot for the new fabric module, remove a fabric module as follows:
a) With your face at least 12 inches (30 cm) away from the front of the fabric module, press both ejector
buttons on the front of the module (see Callout 1 in the following figure).
Caution
Figure 35: Unlocking a Fabric Module from its Slot
1
2
OL-30453-01
Pull the bottom handle to pull the bottom out
about 2 inches (5 cm) to disconnect the
connectors in back.
Do not touch the electrical connectors on the back side and do not set the back side connectors
on anything—always set a fan tray down on a covered side to protect the connectors.
Keep your face away from the front of the fabric module so that the levers do not hit your face
when they spring out from the front of the module.
Press both eject buttons.
Handles spring out from the module.
Cisco Nexus 7718 Switch Site Preparation and Hardware Installation Guide
Installing or Replacing a Fabric Module
3
Pull the handles to partially remove the module
from the slot.
121