Cisco Nexus 7718 Hardware Installation Manual page 117

Table of Contents

Advertisement

Installing or Replacing Modules, Fan Trays, and Power Supplies
b) Press the ejector button next to the handle to release the handle from the front of the module (see Callout
1 in the following figure).
Figure 29: Positioning a Half-Width Supervisor Module to its Slot
1
2
c) Rotate the end of the handle away from the front of the module until it stops (see Callout 1 in the previous
figure).
d) With one hand under the supervisor module and the other hand holding the module by its front, align the
rear of the module to the open supervisor slot.
e) Slide the module onto the guides inside the slot and push the module fully into the slot until you cannot
push the module further.
The front of the module should be about 1/4 inch (0.6 cm) in front of the chassis.
f) Rotate the handle to the front of the module (see Callout 1 in the following figure) until it clicks when it
reaches the front of the module.
OL-30453-01
Rotate the handle fully away from the front of
the module.
Align the bottom of the module to the module
guides in the slot.
Cisco Nexus 7718 Switch Site Preparation and Hardware Installation Guide
Installing or Replacing a Supervisor Module
3
Push the module all the way into the slot (until
it stops and the front is about 1/4 inch in front
of the chassis).
107