21.1. Programming long addresses

As described in chapter 9.2. the long address is split into two CVs.
The byte with the higher value of the address is in CV 17. This
byte determines the range in which the extended address will be
located. For instance, if you enter the value 192 in CV 17 then the
extended address may be between 0 and 255. If 193 is written
into CV 17 then the extended address will be between 256 and
511. You can continue this up to addresses with values of 9984
and 10239. The possible values are shown in figure 31.

21.1.1. Write address

To programm a long address you first of all need to calculate the
values for CV 17 and CV 18 and then programm it. Please note
that it is not possible to programm addresses via the programming
mode "POM".
To programm the long address proceed as follows:
Zuerst legen Sie die gewünschte Adresse fest, zum Beispiel 4007.
First you determine the desired address, for instance 4007.
Then you look for the appropriate address range in Fig. 31. The
value to be entered into CV 17 can be found in the column on the
right. In our example, it is 207.
The value for CV 18 is established as follows:
desired address
minus
first address in the address range -
===============================
equals
value for CV 18
167 is therefore the value to be entered in CV 18. Thus you de-
coder is now programmed to address 4007.

21.1.2. Read out address

If you wish to read out a loco address please read the values of CV
17 and CV 18 one after another and proceed then in reverse order:
Let's assume you have read:
CV 17 = 196; CV 18 = 147. Look up the corresponding address
range in Fig. 31. The first possible address within this range is
1024. Then you have to add the value from CV 18 and you arrive
at the locomotive address:
1024
+
147
====
=
1171
Address range
from
to
0
255
256
511
512
767
768
1023
1024
1279
1280
1535
1536
1791
4007
1792
2047
3840
2048
2303
====
2304
2559
167
2560
2815
2816
3071
3072
3327
3328
3583
Figure 31:
Address range
CV17
from
to
CV17
192
3584 3839
206
193
3840 4095
207
194
4096 4351
208
195
4352 4607
209
196
4608 4863
210
197
4864 5119
211
198
5120 5375
212
199
5376 5631
213
200
5632 5887
214
201
5888 6143
215
202
6144 6399
216
203
6400 6655
217
204
6656 6911
218
205
6912 7167
219
Chart of extended loco addresses
Address range
from
to
CV17
7168
7423
220
7424
7679
221
7680
7935
222
7936
8191
223
8192
8447
224
8448
8703
225
8704
8959
226
8960
9215
227
9216
9471
228
9472
9727
229
9728
9983
230
9984 10239
231