List of all supported CVs (DCC decoders)
CV
Name
31
Index register H
32
Index register L
49
Extended Configuration #1
50
Analogue mode
70
Description
Selection page for CV257-512
Selection page for CV257-512
Further important decoder settings.
Bit
Description
0
Enable Load control (Back-EMF) (not for LokPilot Fx V4.0)
Disable Load control (Back-EMF)
1
DC Motor PWM frequency
20kHz motor pulse frequency
40kHz motor pulse frequency
2
Märklin® Delta Mode
Disable Märklin® Delta Mode
Enable Märklin® Delta Mode
3
Märklin® 2nd address
Disable Märklin® 2nd address
Enable Märklin® 2nd address
4
Automatic DCC speed step detection
Disable DCC speed step detection
Enable DCC speed step detection
5
LGB® function button mode
Disable LGB® function button mode
Enable LGB® function button mode
6
Zimo® Manual Function
Disable Zimo® Manual Function
Enable Zimo® Manual Function
7
Reserved
Selection of allowed analogue modes.
Bit
Function
0
AC Analogue Mode (if so, refer to section 7.3.)
Disable AC Analogue Mode
Enable AC Analogue Mode
1
DC Analogue mode
Disable DC Analogue mode
Enable DC Analogue Mode
Range
Value
16
16
0, 2, 3
0
0 - 255
19
Value
1
0
0
2
0
4
0
8
0
16
0
32
0
64
0
128
0 - 3
3
Value
0
1
0
2