Table 24: Sense data values (Hexadecimal) (Continued)
Sense
Key
ASC
ASCQ
B
43
B
47
B
48
B
80
B
80
B
80
ESL E-Series Tape Library User's Guide
00
SCSI MESSAGE ERROR
Detected message error in message processing on the SCSI BUS.
Verify termination.
Verify SCSI cable connections.
Check host status.
Restart system.
00
SCSI PARITY ERROR
SCSI Parity Error detected.
Verify termination.
Verify SCSI cable connections and cable length.
Check host status.
Restart the system.
00
INITIATOR DETECTED ERROR MESSAGE RECEIVED
01
TRANSFER FULL - AT END OF PLACE
Picker has cartridge in it at end of a place operation (Move Medium
with a target other than the Transfer).
Move cartridge to empty storage element using your application
software. Retry command.
As a last resort, manually remove the tape from the robotics.
06
TRANSFER EMPTY - COMMAND ABORTED
Picker does not contain cartridge at end of pick portion of Move
Medium command.
10
LOAD RETRY FAILED
Library was unable to successfully load and thread the drive, even after
retries.
Check drive alignment.
Make sure the correct media for the drive is being used.
If cartridge loads in another drive successfully, the original drive
may have failed.
Message Name/Description