Table 24: Sense data values (Hexadecimal) (Continued)
Sense
Key
ASC
ASCQ
5
85
5
87
5
87
5
1A
5
2C
ESL E-Series Tape Library User's Guide
F0
HORIZONTAL INVALID COMMAND
Horizontal hardware commanded to position out of system mechanical
limits.
Run th
e Robotics to Home Position
If the problem persists, calibrate the library.
Verify that the host software application is supported, has
up-to-date patches, and is correctly configured.
Verify that the library and its components have the current
firmware.
E0
DEPTH INVALID START CONDITION
Depth hardware condition is unknown. Run the Robotics to Home
Position test from the OCP.
F0
DEPTH INVALID COMMAND
Depth hardware commanded to position out of system mechanical
limits.
Run the
Robotics to Home Position t
If the problem persists, calibrate the library.
Verify that the host software application is supported, has
up-to-date patches, and is correctly configured.
Verify that the library and its components have the current
firmware.
00
PARAMETER LIST LENGTH ERROR
Invalid parameter list length field specified by command.
Verify that the host software application is supported, has
up-to-date patches, and is correctly configured.
Verify that the library and its components have the current
firmware.
00
COMMAND SEQUENCE ERROR (read of unwritten echo buffer)
Message Name/Description