HP StorageWorks ESL E-Series User Manual page 151

Tape library 350799-005
Hide thumbs Also See for StorageWorks ESL E-Series:
Table of Contents

Advertisement

Table 24: Sense data values (Hexadecimal) (Continued)
Sense
Key
ASC
ASCQ
5
8A
5
8B
5
8B
6
28
6
29
6
29
6
29
6
29
6
29
6
80
ESL E-Series Tape Library User's Guide
02
UNCALIBRATED POSITION
System requires calibration. Run the Calibrate Cabinet test from the
OCP.
E0
CLM INVALID START CONDITION
CLM hardware condition is unknown. Run the Robotics to Home Position
test.
F0
CLM INVALID COMMAND
CLM hardware commanded to position out of system mechanical limits.
Run th
e Robotics to Home Position test
If the problem persists, calibrate the library.
01
IMPORT OR EXPORT ELEMENT ACCESSED
Load port door has been closed.
00
POWER-ON, RESET OR BUS DEVICE RESET OCCURRED
Informational message. The host user should assume the inventory may
have changed, and should ask the library for that information again.
01
POWER-ON RESET OCCURRED.
Informational message. The host user should assume the inventory may
have changed, and should ask the library for that information again.
02
BUS RESET OCCURRED.
Informational message. The host user should assume the inventory may
have changed, and should ask the library for that information again.
03
BUS DEVICE RESET OCCURRED
Informational message. The host user should assume the inventory may
have changed, and should ask the library for that information again.
04
INTERNAL DEVICE RESET OCCURRED
Informational message. The host user should assume the inventory may
have changed, and should ask the library for that information again.
00
DOOR WAS OPENED INVENTORY MAY HAVE BEEN CORRUPTED
Close door and retry command after inventory is complete.
Message Name/Description
Sense Data Values
.
151

Advertisement

Table of Contents
loading

Table of Contents