Table 24: Sense data values (Hexadecimal) (Continued)
Sense
Key
ASC
ASCQ
5
25
5
26
5
26
ESL E-Series Tape Library User's Guide
00
LOGICAL UNIT IS NOT SUPPORTED
Verify the logical unit field specified in the command contains a
legitimate logical unit number.
Check cabling to logical unit.
Verify that the host software application is supported, has
up-to-date patches, and is correctly configured.
Verify that the library and its components have the current
firmware.
00
INVALID FIELD IN PARAMETER LIST
Verify Mode Select page fields.
Verify that fields comply with command format described in this
guide.
Verify that the host software application is supported, has
up-to-date patches, and is correctly configured.
Verify that the library and its components have the current
firmware.
02
PARAMETER VALUE INVALID
Verify Mode Select page fields.
Verify that fields comply with command format described in this
guide.
This response is also returned for commands issued to the diagnostic
interface of the library if an invalid parameter is sent.
Verify that the host software application is supported, has
up-to-date patches, and is correctly configured.
Verify that the library and its components have the current
firmware.