Panasonic S-36PU1E5A Service Manual page 71

Table of Contents

Advertisement

Single -Type
1-1. Unit Specifi cations
PE1
3. Wall Mounted Type S-60PK1E5A / U-60PE1E5A
INDOOR
MODEL
PANEL
MODEL
OUTDOOR
MODEL
Branch pipe
MODEL
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
C
ANNUAL CONSUMPTION TOTAL kWh *4
O
EER/EER CLASS
TOTAL(W/W)*5/("A"~"G")
O
Pdsign
L
SEER
(W/W)
Erp
I
Annual consumption
*6
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
H
COP/COP CLASS
TOTAL(W/W)*5/("A"~"G")
E
Pdsign
A
Tbivalen
T
Erp
SCOP
(W/W)
I
*6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W)
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE (ΩMAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
3
I/D AIR
COOL
m
/min (ft
3
FLOW
HEAT
m
/min (ft
COOL
m
3
/min (ft
O/D AIR
FLOW
3
HEAT
m
/min (ft
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Cool O.D(DBT)
Operation
Condition
Heat O.D(DBT)
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
P
PIPE LENGTH RANGE
I
I/D&O/D HEIGHT DIFFERENCE m (ft)
N
ADD GAS AMOUNT g/m (oz/ft)
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1: In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
*2: If the EUROVENT Certifi ed models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3: Network Impedance shall be applicable for EUROPE and CHINA models.
*4: The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5: EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6: SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
S-60PK1E5A
-
ø, Hz
1ø 50Hz
V
220
230
kW
6.0
6.0
20500
20500
A
0.59
0.58
W
57
57
-
-
-
-
kW
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
47/44/40
64/59/54
dB-A
kW
7.0
7.0
23900
23900
A
0.59
0.58
W
57
57
-
-
-
kW
-
-
°C
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
47/44/40
64/59/54
dB-A
-
-
0.59/57
0.58/57
-
-
-
47
L/h(Pt/h)
3.4
Pa
-
3
/min)
18/14.5/11.5 (636/512/406)
3
/min)
18/14.5/11.5 (636/512/406)
3
/min)
3
/min)
300 (11-1/32)
1065 (41-23/64)
230 (9-1/32)
310
1140
380
14.5 (32)
18 (40)
15 (16)
18°C ~ 32°C
16°C ~ 30°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
-
U-60PE1E5A
-
ISO5151 / EN14511 / EN14825 / EN12102
1ø 50Hz
240
220
230
6.0
20500
0.52
7.45
7.15
57
1.500k
1.500k
1.560k
1.560k
-
780
-
3.85
3.85 / A
-
-
6.0
-
-
6.6
-
-
318
-
-
A++
-
92
91
48/-
65/-
7.0
23900
0.52
8.45
8.15
57
1.760k
1.760k
1.820k
1.820k
-
3.85
3.85 / A
-
-
6.0
-
-
-10
-
-
3.9
-
-
2154
-
-
A
-
95
94
-
-
50/-
67/-
-
0.52/57
18.0/3.800k
18.0/3.930k
-
8.45/1.7k
8.15/1.7k
-
90
(7.1)
-
60
60
R410A
2.00k
996 (39-7/32)
940 (37-1/32)
340 (13-13/32)
1136
1055
485
68 (150)
76 (168)
2 (3)
-15°C ~ 46°C
-20°C ~ 24°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
5 ~ 50
(16.4 ~ 164.0)
(49.2/98.4)
50
(0.538)
30
(98.4)
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
1-61
240
Min
Max
2.5
7.1
8500
24200
6.95
-
-
1.500k
-
-
1.560k
450
2.000k
-
-
-
3.85
5.56
3.55
-
-
-
-
90
-
-
2.0
8.0
6800
27300
7.90
-
-
1.760k
-
-
1.820k
400
2.480k
3.85
5.00
3.23
-
-
-
-
-
93
-
-
18.0/4.060k
7.90/1.7k
(2119)
(2119)
(70.5)
/
/
/
/
/
/
/
/
/
~
~
1