Panasonic S-36PU1E5A Service Manual page 199

Table of Contents

Advertisement

Single -Type
1-1. Unit Specifi cations
PEY1
4. Low Silhouette Ducted Type S-140PF1E5A / U-140PEY1E8
INDOOR
MODEL
PANEL
MODEL
OUTDOOR
MODEL
Branch pipe
MODEL
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
C
ANNUAL CONSUMPTION TOTAL kWh *4
O
EER/EER CLASS
TOTAL(W/W)*5/("A"~"G")
O
Pdsign
L
SEER
(W/W)
Erp
I
Annual consumption
*6
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
H
COP/COP CLASS
TOTAL(W/W)*5/("A"~"G")
E
Pdsign
A
Tbivalen
T
Erp
SCOP
(W/W)
I
*6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W)
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE (ΩMAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
3
I/D AIR
COOL
m
/min (ft
3
FLOW
HEAT
m
/min (ft
COOL
m
3
/min (ft
O/D AIR
FLOW
3
HEAT
m
/min (ft
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Cool O.D(DBT)
Operation
Condition
Heat O.D(DBT)
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
P
PIPE LENGTH RANGE
I
I/D&O/D HEIGHT DIFFERENCE m (ft)
N
ADD GAS AMOUNT g/m (oz/ft)
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1: In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
*2: If the EUROVENT Certifi ed models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3: Network Impedance shall be applicable for EUROPE and CHINA models.
*4: The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5: EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6: SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
S-140PF1E5A
ø, Hz
1ø 50Hz
V
220
230
kW
14.0
14.0
47800
47800
A
1.55
1.50
W
225
225
-
-
-
-
kW
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
40/36/33
62/58/55
dB-A
kW
14.0
14.0
47800
47800
A
1.55
1.50
W
225
225
-
-
-
kW
-
-
°C
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
40/36/33
62/58/55
dB-A
-
-
1.91/285
1.86/285
-
-
-
200
L/h(Pt/h)
9.0
Pa
100 (MIN10 - MAX150)
3
/min)
36/32/25 (1271/1130/883)
3
/min)
36/32/25 (1271/1130/883)
3
/min)
3
/min)
290 (11-13/32)
1400 (55-1/8)
700 (27-9/16)
355
1614
850
45 (99)
54 (119)
9 (10)
18°C ~ 32°C
16°C ~ 30°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
U-140PEY1E8
-
ISO13253 / EN14511 / EN12102
3ø 50Hz
240
380
400
14.0
47800
1.47
6.75
6.45
225
4.125k
4.125k
4.350k
4.350k
-
2175
-
3.22
3.22 / A
-
-
-
-
-
-
-
-
-
-
-
-
-
93
92
-
-
54/-
71/-
14.0
47800
1.46
5.60
5.40
225
3.355k
3.355k
3.580k
3.580k
-
3.91
3.91 / A
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
91
90
-
-
53/-
70/-
-
1.81/285
10.0/6.200k
10.0/6.500k
-
6.75/3.0k
6.45/3.0k
-
90×2
(18.9)
-
135
120
R410A
3.40k
1416 (55-3/4)
940 (37-1/32)
340 (13-13/32)
1556
1055
485
98 (216)
108 (238)
1 (2)
-10°C ~ 43°C
-15°C ~ 24°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
5 ~ 50
(16.4 ~ 164.0)
(49.2/98.4)
50
(0.538)
30
(98.4)
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
1-189
415
Min
Max
3.3
15.5
11300
52900
6.25
-
-
4.125k
-
-
4.350k
840
6.000k
-
-
-
3.22
3.93
2.58
-
-
-
-
92
-
-
4.1
16.0
14000
54600
5.20
-
-
3.355k
-
-
3.580k
900
5.200k
3.91
4.56
3.08
-
-
-
-
-
90
-
-
10.0/6.750k
6.25/3.0k
(4767)
(4238)
(119.9)
/
/
/
/
/
/
/
/
/
~
~
1