F04 Compressor Discharge Temperature Sensor (TD) Trouble
1.
Error Detection Method
It is judged an error based on the criteria listed below.
•
Open circuit or Short circuit
2.
Error Diagnosis
1 Sensor
1-1
Sensor connector is connected to PC board properly.
1-2
Sensor is correctly installed at holder side.
1-3
Abnormal temperature exists even after replacing sensor.
2 PC board
Resistance between connector pins on PC board is less than
2-1
1 k ohm
2-2
Abnormal temperature exists even after replacing PC board.
3 Operating
3-1
Peripheral temperature of outdoor unit is over 46°C.
status
3-2
Tends to have insufficient refrigerant charge in the system.
3-3
Check noise.
5-29
Yes
1-2
No
Reconnect and check
Yes
Replace sensor
No
Correct and see what
happens.
1-3
Yes
2-1
No
See what happens.
Yes
Replace PC board
No
2-2
Yes
3-1
No
See what happens.
Yes
Correct
No
3-2
Adjust the amount
Yes
of refrigerant
No
3-3
5