1-13. Capacity Table
1. Cooling Capacity Performance Data
•
Combination of Multiple Unit
Ducted Type
Ambient
Power
Model
Return
Source
DB
23
25
220V
230V
S-60PN1E5A×2
240V
U-125PE1E5A
27
50Hz
(U-125PE1E8A)
1 phase
(3 phase)
29
32
23
25
220V
230V
S-50PN1E5A×3
240V
U-140PE1E5A
27
50Hz
(U-140PE1E8A)
1 phase
(3 phase)
29
32
23
25
220V
230V
S-71PN1E5A×2
240V
U-140PE1E5A
27
50Hz
(U-140PE1E8A)
1 phase
(3 phase)
29
32
25°C
Air
WB
TC
SHC
IPT
TC
16
12.7
10.4
3.90
12.7
19
13.6
7.7
4.06
13.6
22
14.9
4.9
4.20
14.9
16
13.2
12.7
3.96
13.2
19
14.1
9.8
4.13
14.1
22
15.4
7.0
4.27
15.4
16
13.6
13.6
4.03
13.6
19
14.6
12.0
4.20
14.6
22
16.0
9.2
4.35
16.0
16
13.8
13.8
4.04
13.8
19
14.8
14.1
4.21
14.8
22
16.2
11.2
4.36
16.2
16
14.0
14.0
4.05
14.0
19
15.0
14.3
4.22
15.0
22
16.4
11.4
4.37
16.4
16
14.1
11.4
5.03
14.1
19
15.1
8.4
5.25
15.1
22
16.5
5.5
5.43
16.5
16
14.6
13.8
5.12
14.6
19
15.6
10.7
5.34
15.6
22
17.1
7.8
5.52
17.1
16
15.1
15.1
5.20
15.1
19
16.1
13.1
5.43
16.1
22
17.7
10.0
5.61
17.7
16
15.3
15.3
5.21
15.3
19
16.4
15.4
5.44
16.4
22
17.9
12.3
5.63
17.9
16
15.5
15.5
5.23
15.5
19
16.6
15.6
5.45
16.6
22
18.2
12.5
5.64
18.2
16
14.1
11.0
5.03
14.1
19
15.1
8.2
5.25
15.1
22
16.5
5.5
5.43
16.5
16
14.6
13.2
5.12
14.6
19
15.6
10.4
5.34
15.6
22
17.1
7.5
5.52
17.1
16
15.1
15.1
5.20
15.1
19
16.1
12.5
5.43
16.1
22
17.7
9.8
5.61
17.7
16
15.3
15.3
5.21
15.3
19
16.4
14.7
5.44
16.4
22
17.9
11.8
5.63
17.9
16
15.5
15.5
5.23
15.5
19
16.6
14.9
5.45
16.6
22
18.2
12.0
5.64
18.2
Outdoor air intake temp(°C D.B.)
30°C
35°C
SHC
IPT
TC
SHC
IPT
10.5
4.18
12.2
10.2
4.45
7.7
4.36
13.1
7.4
4.64
4.9
4.52
14.3
4.7
4.80
12.8
4.26
12.7
12.4
4.53
9.8
4.44
13.5
9.5
4.72
6.9
4.59
14.8
6.8
4.88
13.6
4.33
13.1
13.1
4.60
12.1
4.51
14.0
11.6
4.80
9.3
4.67
15.3
8.9
4.97
13.8
4.34
13.3
13.3
4.61
14.1
4.52
14.2
13.6
4.81
11.3
4.68
15.6
11.0
4.98
14.0
4.35
13.5
13.5
4.62
14.3
4.53
14.4
13.8
4.82
11.5
4.69
15.8
11.1
4.99
11.5
5.40
13.6
11.2
5.75
8.5
5.64
14.5
8.2
6.00
5.4
5.83
15.9
5.3
6.21
13.9
5.50
14.0
13.5
5.85
10.8
5.73
15.0
10.4
6.10
7.7
5.93
16.4
7.5
6.31
15.1
5.59
14.5
14.5
5.94
13.2
5.83
15.5
12.7
6.20
10.1
6.03
17.0
9.7
6.41
15.3
5.60
14.7
14.7
5.96
15.5
5.84
15.7
14.9
6.22
12.4
6.04
17.2
11.9
6.43
15.5
5.61
14.9
14.9
5.97
15.7
5.86
16.0
15.2
6.23
12.6
6.06
17.5
12.1
6.45
11.0
5.40
13.6
10.8
5.75
8.3
5.64
14.5
8.0
6.00
5.5
5.83
15.9
5.3
6.21
13.2
5.50
14.0
12.9
5.85
10.4
5.73
15.0
10.1
6.10
7.6
5.93
16.4
7.3
6.31
15.1
5.59
14.5
14.5
5.94
12.6
5.83
15.5
12.2
6.20
9.7
6.03
17.0
9.5
6.41
15.3
5.60
14.7
14.7
5.96
14.8
5.84
15.7
14.2
6.22
11.9
6.04
17.2
11.5
6.43
15.5
5.61
14.9
14.9
5.97
15.0
5.86
16.0
14.5
6.23
12.1
6.06
17.5
11.7
6.45
1-423
TC
:Cooling Capacity
SHC :Sensible Heat Capacity
IPT :Cooling Power Consumption
40°C
46°C
TC
SHC
IPT
TC
SHC
11.4
10.0
4.63
8.3
8.3
12.2
7.2
4.83
8.9
5.9
13.3
4.4
5.00
9.7
3.2
11.8
11.8
4.71
8.6
8.6
12.6
9.3
4.91
9.2
7.8
13.8
6.5
5.08
10.1
5.1
12.2
12.2
4.79
8.9
8.9
13.0
11.5
4.99
9.5
9.5
14.3
8.7
5.16
10.4
7.1
12.4
12.4
4.80
9.0
9.0
13.2
13.2
5.00
9.7
9.7
14.5
10.7
5.18
10.6
9.2
12.6
12.6
4.81
9.2
9.2
13.4
13.4
5.02
9.8
9.8
14.7
10.9
5.19
10.7
9.3
12.6
10.9
5.98
9.2
9.2
13.5
7.9
6.24
9.8
6.4
14.8
4.9
6.45
10.8
3.6
13.1
13.1
6.08
9.5
9.5
13.9
10.1
6.34
10.2
8.6
15.3
7.1
6.56
11.2
5.7
13.5
13.5
6.18
9.9
9.9
14.4
12.6
6.45
10.5
10.5
15.8
9.5
6.67
11.5
7.8
13.7
13.7
6.20
10.0
10.0
14.6
14.6
6.46
10.7
10.7
16.0
11.7
6.69
11.7
10.0
13.9
13.9
6.21
10.2
10.2
14.8
14.8
6.48
10.9
10.9
16.3
11.9
6.70
11.9
10.2
12.6
10.4
5.98
9.2
8.9
13.5
7.7
6.24
9.8
6.2
14.8
4.9
6.45
10.8
3.6
13.1
12.7
6.08
9.5
9.5
13.9
9.7
6.34
10.2
8.2
15.3
6.9
6.56
11.2
5.5
13.5
13.5
6.18
9.9
9.9
14.4
12.0
6.45
10.5
10.3
15.8
9.1
6.67
11.5
7.4
13.7
13.7
6.20
10.0
10.0
14.6
14.0
6.46
10.7
10.7
16.0
11.2
6.69
11.7
9.4
13.9
13.9
6.21
10.2
10.2
14.8
14.2
6.48
10.9
10.9
16.3
11.4
6.70
11.9
9.6
1
unit : kW
IPT
3.78
3.95
4.08
3.85
4.01
4.15
3.91
4.08
4.22
3.92
4.09
4.23
3.93
4.10
4.24
4.89
5.10
5.27
4.97
5.18
5.36
5.05
5.27
5.45
5.06
5.28
5.47
5.08
5.30
5.48
4.89
5.10
5.27
4.97
5.18
5.36
5.05
5.27
5.45
5.06
5.28
5.47
5.08
5.30
5.48