Panasonic S-36PU1E5A Service Manual page 203

Table of Contents

Advertisement

Simultaneous (Twin) -Type
1-1. Unit Specifi cations
PEY1
5. Ducted Type S-60PN1E5A×2 / U-125PEY1E5
INDOOR
MODEL
PANEL
MODEL
OUTDOOR
MODEL
Branch pipe
MODEL
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
C
ANNUAL CONSUMPTION TOTAL kWh *4
O
EER/EER CLASS
TOTAL(W/W)*5/("A"~"G")
O
Pdsign
L
SEER
(W/W)
Erp
I
Annual consumption
*6
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
H
COP/COP CLASS
TOTAL(W/W)*5/("A"~"G")
E
Pdsign
A
Tbivalen
T
Erp
SCOP
(W/W)
I
*6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W) 1.28×2/160×2 1.24×2/160×2 1.20×2/160×2 29.0/6.000k
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE (ΩMAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
3
I/D AIR
COOL
m
/min (ft
3
FLOW
HEAT
m
/min (ft
COOL
m
3
/min (ft
O/D AIR
FLOW
3
HEAT
m
/min (ft
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Cool O.D(DBT)
Operation
Condition
Heat O.D(DBT)
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
P
PIPE LENGTH RANGE
I
I/D&O/D HEIGHT DIFFERENCE m (ft)
N
ADD GAS AMOUNT g/m (oz/ft)
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1: In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
*2: If the EUROVENT Certifi ed models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3: Network Impedance shall be applicable for EUROPE and CHINA models.
*4: The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5: EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6: SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
S-60PN1E5A×2
-
ø, Hz
1ø 50Hz
V
220
230
kW
12.5
12.5
42700
42700
A
1.12×2
1.08×2
W
140×2
140×2
-
-
-
-
kW
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
43/41/36
60/58/53
dB-A
kW
12.5
12.5
42700
42700
A
1.12×2
1.08×2
W
140×2
140×2
-
-
-
kW
-
-
°C
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
43/41/36
60/58/53
dB-A
-
-
-
-
-
120×2
L/h(Pt/h)
7.9
(3.95×2)
Pa
50 (MIN10 ~ MAX80)
3
/min)
[22/20/16 (777/706/565)]×2
3
/min)
[22/20/16 (777/706/565)]×2
3
/min)
3
/min)
250 (9-27/32)
1000 (+100) 39-5/16 (+3-15/16)
650 (25-19/32)
338
1211
761
32 (71)
38 (84)
6 (7)
18°C ~ 32°C
16°C ~ 30°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
U-125PEY1E5
CZ-P155BK1
ISO13253 / EN14511 / EN12102
1ø 50Hz
240
220
230
12.5
42700
1.04×2
19.9
19.0
140×2
4.165k
4.165k
4.445k
4.445k
-
2223
-
2.81
2.81 / C
-
-
-
-
-
-
-
-
-
-
-
-
-
95
95
-
-
56/-
73/-
12.5
42700
1.04×2
16.2
15.5
140×2
3.385k
3.385k
3.665k
3.665k
-
3.41
3.41 / B
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
95
95
-
-
56/-
73/-
-
29.0/6.300k
-
19.9/3.0k
19.0/3.0k
-
90
(16.6)
-
80
73
R410A
3.20k
996 (39-7/32)
940 (37-1/32)
340 (13-13/32)
1136
1055
485
85 (187)
93 (205)
2 (3)
-10°C ~ 43°C
-15°C ~ 24°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
5 ~ 50
(16.4 ~ 164.0)
(49.2/98.4)
50
(0.538)
30
(98.4)
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
1-193
240
Min
Max
3.8
13.5
13000
46100
18.4
-
-
4.165k
-
-
4.445k
950
5.200k
-
-
-
2.81
4.00
2.60
-
-
-
-
94
-
-
3.4
15.0
11600
51200
15.0
-
-
3.385k
-
-
3.665k
780
4.600k
3.41
4.36
3.26
-
-
-
-
-
94
-
-
29.0/6.600k
18.4/3.0k
(2825)
(2578)
(112.9)
/
/
/
/
/
/
/
/
/
~
~
1

Hide quick links:

Advertisement

Table of Contents
loading